Diode Test

 

Test current of 1mA maximum, open circuit voltage 2.8V DC typical 

Continuity Check

 

Audible signal will sound if the resistance is less than approx 30

 

Battery Test current 

9V (6mA); 1.5V (100mA) 

Input Impedance

 >1M

 

ACV Bandwidth 

45Hz to 450Hz 

DCA voltage drop 

200mV 

Display 

3 ½ digit,

 

2000 count LCD, 0.5” digits 

Over range indication

 

“1” is displayed 

Polarity

 

Automatic (no indication for positive polarity); Minus (-) sign for negative 
polarity. 

Measurement Rate 

2 times per second, nominal 

Low Battery Indication 

“BAT”

 is displayed if battery voltage drops below operating voltage 

Battery

 

one 9 volt (NEDA 1604) battery

 

Fuses

  

mA, 

A ranges; 0.2A/250V fast blow 

A range; 10A/250V fast blow 

Operating Temperature

 32

o

F to 122

o

F (0

o

C to 50

o

C) 

Storage Temperature

 -4

o

F to 140

o

F (-20

o

C to 60

o

C) 

Relative Humidity 

<70% operating, <80% storage 

Operating Altitude 

7000ft. (2000) meters maximum. 

Weight

  

9.17 oz. (260g). 

Size

  

4.78” x 2.38” x 1.57” (121.5mm x 60.6mm x 40mm) 

Approvals 

UL, CE 

Safety 

For indoor use and in accordance with Overvoltage Category II 600V, 
Pollution Degree 2. Category II includes local level, appliance, portable 
equipment, etc., with transient overvoltages less than Overvoltage 
Category III. 

UL Listed 

The UL mark does not indicate that this product has been evaluated for 
the accuracy of its readings. 

 
 
 
 

www.ponpe.com

contact:

sale@ponpe.com

Summary of Contents for MiniTec MN24

Page 1: ...User s Manual MiniTecTM Series MultiMeter Model MN24 www ponpe com contact sale ponpe com...

Page 2: ...he meter 2 Make sure any covers or battery doors are properly closed and secured 3 Always remove the test leads before replacing the battery or fuses 4 Inspect the condition of the test leads and the...

Page 3: ...ositive jack Note Tilt stand fuse and battery compartment are located on the rear of the unit Symbols Continuity Diode test micro amps m milli volts amps k kilo ohms ohms VDC volts direct current VAC...

Page 4: ...ve mA jack for currents to 200mA b Positive 10A jack for currents to 10A 2 Turn the rotary switch to the ADC range needed 3 Touch the test probes in series with the circuit under test and read the cur...

Page 5: ...s will indicate near 0mV and an open device will indicate I in both polarities Battery Test 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into t...

Page 6: ...e meter in mild ambient conditions Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts 3 Handle the meter gently Dropping it can damage the electronic p...

Page 7: ...he battery door and secure with the screw Fuse Replacement WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing rear cover 1 Disconnect the test leads f...

Page 8: ...ng 2 digits 10A 10mA 2 0 reading 2 digits Resistance 200 0 1 0 8 reading 2 digits 2000 1 20k 0 01k 200k 0 1k 2000k 1k 1 0 reading 2 digits Battery Test 9V 10mV 1 0 reading 2 digits 1 5V 10mV Input Lim...

Page 9: ...w operating voltage Battery one 9 volt NEDA 1604 battery Fuses mA A ranges 0 2A 250V fast blow A range 10A 250V fast blow Operating Temperature 32 o F to 122 o F 0 o C to 50 o C Storage Temperature 4...

Page 10: ...ages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibrati...

Reviews: