RESISTANCE MEASUREMENTS 

WARNING: 

To avoid electric shock, disconnect power to the unit under test and discharge 

all capacitors before taking any resistance measurements. 

1. 

Set the function switch to the highest 

Ω 

 position.  

2.  Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

Ω

 jack. 

3.  Touch the test probe tips across the circuit or part under test. 
4.  Read the resistance in the display. Move the function switch to 

successively lower 

Ω

 ranges to obtain a higher resolution reading. 

 
 
 

CONTINUITY CHECK 

WARNING: 

To avoid electric shock, never measure continuity on circuits that have a 

voltage potential. 

1. 

Set the function switch to the 

 position. 

2.  Insert the black lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

Ω

 jack. 

3.  Touch the test probe tips to the circuit or wire you wish to check.  

4.  If the resistance is less than approximately 100

Ω

, the audible signal 

will sound. If the circuit is open, the display will indicate “

1.     

”. 

 
 
 
 
 

DIODE TEST 

1. 

Set the function switch to the 

 position. 

2.  Insert the black test lead banana plug into the negative 

COM

 jack  

Insert the red test lead banana plug into the positive 

 

jack. 

3.  Touch the test probes to the diode under test. 
4.  A typical diode will indicate approximately .400 to .500 volts for the 

forward test and “

1.     

” for the reverse test. 

5.  A shorted diode will indicate a low value in both the reverse and 

forward test directions. An open diode will indicate “

1.    

” in both test 

directions. 

 

Summary of Contents for MN15A

Page 1: ...User s Guide Mini Digital Multimeter Model MN15A A...

Page 2: ...symbol indicates that a device is protected throughout by double insulation or reinforced insulation SAFETY INSTRUCTIONS This meter has been designed for safe use but must be operated with caution The...

Page 3: ...jack for voltage milliamp resistance continuity diode and temperature functions 5 COM test lead jack 6 Battery compartment rear SYMBOLS Continuity Diode AC DC M megga 10 6 ohms m milli 10 3 volts amps...

Page 4: ...eing switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function switch to the 600 VAC position 2 Insert the black test lead banana plug into the negative COM jack I...

Page 5: ...the 200mA position and insert the red test lead banana plug into the mA jack 3 For current measurements up to 10A set the function switch to the 10A position and insert the red test lead banana plug i...

Page 6: ...e potential 1 Set the function switch to the position 2 Insert the black lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive jack 3 Touch the test probe...

Page 7: ...positive V jack 3 Touch the black test probe tip to the negative side of the battery Touch the red test probe tip to the positive side of the battery 4 Read the voltage in the display TEMPERATURE MEA...

Page 8: ...hould be removed to prevent damage to the unit BATTERY FUSE INSTALLATION and LOW BATTERY INDICATION WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing...

Page 9: ...10A 10mA 2 0 reading 2 digits Resistance 200 0 1 0 8 reading 2 digits 2000 1 20k 0 01k 200k 0 1k 20M 10k 1 5 reading 2 digits Battery Test 9V 10mV 1 0 reading 2 digits 1 5V 1mV Temperature 20 C to 75...

Page 10: ...e insulation per EN61010 1 and IEC61010 1 2nd Edition 2001 to CAT III 600V Pollution Degree 2 The meter also meets UL 61010 1 Second Edition 2004 CAN CSA C22 2 No 61010 1 Second Edition 2004 and UL 61...

Page 11: ...sponsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wir...

Page 12: ...MN15A V1 1 02 09 12...

Reviews: