background image

RHT10 HW_SW-en-US_V5.6.2   6/16 

10

To

 

customize

 

the

 

graph

 

window

 

select

 

SHOW

 

TRACES,

 

BACKGROUND,

 

GRID

 

LINES,

 

and

 

MASK

 

POINTS

 

from

 

the

 

VIEW

 

pull

down

 

menu.

 

These

 

options

 

provide

 

the

 

following

 

features:

 

 

SHOW

 

TRACES:

 

Allows

 

the

 

user

 

to

 

select

 

which

 

data

 

to

 

view

 

as

 

a

 

trace

 

(Temperature

 

&

 

Alarms).

 

BACKGROUND:

 

Select

 

background

 

color

 

scheme.

 

GRID

 

LINES:

 

Add

 

or

 

remove

 

grid

 

lines

 

from

 

x

 

and

 

y

 

axes.

 

MASK

 

POINTS:

 

Places

 

dots

 

on

 

the

 

traces

 

for

 

the

 

actual

 

data

 

points,

 

breaking

 

up

 

the

 

continuous

 

nature

 

of

 

the

 

trace.

 

 

 

FILE

 

OPEN,

 

FILE

 

SAVE

AS

 

 

To

 

save

 

the

 

transferred

 

data

 

in

 

a

 

format

 

other

 

than

 

the

 

proprietary

 

.rec

 

format,

 

click

 

the

 

SAVE

 

AS

 

icon

 

from

 

the

 

menu

 

bar

 

(4

th

 

from

 

right)

 

or

 

select

 

SAVE

 

AS

 

from

 

the

 

FILE

 

pull

down

 

menu.

  

The

 

data

 

can

 

be

 

saved

 

in

 

the

 

following

 

formats:

 

 

TEXT

 

FILE

 

(.txt)

 

EXCEL

 

FILE

 

(.xls)

 

BITMAP

 

FILE

 

(.bmp)

 

 

To

 

open

 

an

 

existing

 

data

 

file

 

for

 

viewing

 

on

 

the

 

data

 

graph

 

window,

 

click

 

on

 

the

 

FILE

 

OPEN

 

icon

 

on

 

the

 

menu

 

bar

 

(3

rd

 

from

 

left),

 

or

 

select

 

FILE

 

OPEN

 

from

 

the

 

FILE

 

pull

down

 

menu.

  

When

 

prompted,

 

select

 

a

 

.rec

 

file

 

saved

 

earlier.

 

 

FILE

 

PRINT

 

 

To

 

print

 

a

 

data

 

graph

 

window

 

to

 

a

 

line

 

or

 

network

 

printer,

 

click

 

on

 

the

 

printer

 

icon

 

or

 

select

 

PRINT

 

from

 

the

 

FILE

 

pull

down

 

menu.

  

Note

 

that

 

color

 

graph

 

windows

 

can

 

be

 

accurately

 

printed

 

on

 

color

 

printers.

 

 

Note:

 

The

 

RHT10

 

retains

 

data

 

in

 

its

 

internal

 

memory

 

until

 

the

 

user

 

begins

 

a

 

new

 

logging

 

session.

  

Starting

 

a

 

new

 

logging

 

session

 

clears

 

all

 

of

 

the

 

RHT10’s

 

stored

 

readings;

 

be

 

sure

 

to

 

save

 

previous

 

data

 

before

 

starting

 

a

 

new

 

logging

 

session.

 

 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for RHT10

Page 1: ...USER GUIDE Humidity Temperature Datalogger Model RHT10 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...upplied with a long life lithium battery which can typically allow logging for one year This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Features Memory for 32 000 readings 16 000 temperature and 16 000 humidity ...

Page 3: ...iption 1 Protective cover 2 USB connector to PC port 3 Start button 4 RH and Temperature sensors 5 Alarm LED red yellow 6 Record LED green 7 Mounting clip www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 4: ...automatically open and provide on screen prompts open and browse the CD ROM drive then find and double click on the SETUP EXE file included on the program disk Follow the on screen prompts to complete the installation Software Install Run SETUP up exe and follow the defaults to install he RTH10 software USB Driver Install 1 Open the root folder of the RHT10 2 Open the folder Driver DriverUSBXPRESS...

Page 5: ...aph icon on your desktop to launch the program The opening screen will appear as shown below Click on Connect to open the main screen Click on About to view the version number Click on View File to open an existing file Click on Quit to close the program www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 6: ...Setup window will appear as shown below descriptions for each field in the Setup window are listed directly below the illustration The CURRENT TIME field will automatically synchronize with the PC date and time setting The MANUAL and INSTANT select buttons allow the user to start data logging immediately when the Setup window is exited INSTANT or at a later time MANUAL The LOGGER NAME field allows...

Page 7: ...cting a specified number of sample points Always ensure that the remaining charge in the battery is sufficient to last the complete duration of your logging exercise When in doubt we recommend that you always install a fresh battery before logging critical data If INSTANT was selected in the SETUP window the RHT10 begins logging at the instant the SETUP button is pressed If MANUAL was selected the...

Page 8: ...gs If the readings are successfully transferred the VIEW screen and the SAVE screen both shown below will appear In the SAVE screen name the file and save it to a convenient location The data is saved as an rec file for use in this program only At a later time the user can select SAVE AS and save the data as an Excel Text or Bitmap file explained in next section In the screen below press VIEW to s...

Page 9: ...lick and drag a box around any data area to magnify the selected area 2 Click on the zoom magnifier icon tool on the menu bar 3 Select VIEW ALL or ZOOM OUT from the VIEW pull down menu In the example graph above the Temperature is represented by the solid red line the lines are known as traces the RH and Dew Point are represented by the solid yellow and green lines respectively The low and high al...

Page 10: ... the FILE pull down menu The data can be saved in the following formats TEXT FILE txt EXCEL FILE xls BITMAP FILE bmp To open an existing data file for viewing on the data graph window click on the FILE OPEN icon on the menu bar 3rd from left or select FILE OPEN from the FILE pull down menu When prompted select a rec file saved earlier FILE PRINT To print a data graph window to a line or network pr...

Page 11: ...part number RHT10 SW Note that the standard RHT10 software must be un installed before the optional RHT10 SW software can be installed To view GPP data click on the VIEW menu heading and scroll down to the SHOW TRACES tab Ensure that the GPP line is checked If checked the graph will display GPP data If unchecked the graph will not show GPP data www GlobalTestSupply com Find Quality Products Online...

Page 12: ...ce battery Record Alarm Yellow single flash every 10 sec Logging low alarm for TEMP Yellow double flash every 10 sec Logging high alarm for TEMP Yellow single flash every 60 sec RHT10 memory full Download data To save power the RHT10 s LED flashing cycle can be changed to 20s or 30s via the supplied software To save power alarm LEDs for temperature can be disabled via the supplied software When th...

Page 13: ...erature Overall Range 40 to 158o F 40 to 70o C Accuracy 25o C 40 to 100 RH 4 0o F 2o C Grains per pound 1120 gpp 160g kg max Available only with optional RHT10 SW software Logging rate Selectable sampling interval From 2 seconds up to 24 hours Operating temperature 31 to 176o F 35 to 80o C Battery type 3 6V Lithium 1 2 AA SAFT LS14250 Tadiran TL 5101 or equivalent Battery life 1 year typ depending...

Page 14: ... Before replacing the battery remove the datalogger from the PC Follow diagrammatic steps 1 through 4 below NOTE Leaving the RHT10 plugged into the PC USB port longer than necessary will cause some of the battery capacity to be lost WARNING Handle lithium batteries carefully observe warnings on battery casing Dispose of in accordance with local regulations Safety Please dispose of batteries respon...

Page 15: ... Inc specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Cust...

Reviews: