background image

RHT10 HW_SW-en-US_V5.6.2   6/16 

12

RHT10

 

LED

 

STATUS

 

GUIDE

 

 

 

 
 

LEDs

 

Meaning

Action

 

  

Record

      

Alarm

 

No

 

LEDs

 

flashing

 

No

 

logging

 

in

 

process

 

Or

 

No

 

battery

 

found

 

Or

 

Battery

 

completely

 

discharged

  

Fit

 

battery

 

in

 

place

 

 

Replace

 

the

 

battery

 

and

 

download

 

the

 

data

 

 

  

Record

      

Alarm

 

Green

 

single

 

flash

 

every

 

10

 

sec.

 

*

 

    ‐

Logging,

 

no

 

alarm**

 

 

Green

 

double

 

flash

 

every

 

10

 

sec.

 

*

 

    ‐

Delayed

 

start

 

To

 

start,

 

Hold

 

the

 

start

 

button

 

until

 

Green

 

and

 

Yellow

 

LED

 

flash

 

 

  

Record

      

Alarm

 

 

Red

 

single

 

flash

 

every

 

10

 

sec.

 

*

 

    ‐

Logging,

 

low

 

alarm

 

for

 

RH

 

Red

 

double

 

fl

ash

 

every

 

10

 

sec.

 

 

    ‐

Logging,

 

high

 

alarm

 

for

 

RH

 

 

Red

 

single

 

flash

 

every

 

60

 

sec.

 

    ‐ 

Low

 

Battery

 

 

 

Logging,

 

if

 

enabled,

 

will

 

stop

 

automatically.

 

No

 

data

 

will

 

be

 

lost.

 

Replace

 

battery

 

 

  

Record

      

Alarm

 

Yellow

 

single

 

flash

 

every

 

10

 

sec.

 

*

 

 ‐

Logging,

 

low

 

alarm

 

for

 

TEMP

 

Yellow

 

double

 

fl

ash

 

every

 

10

 

sec.

 

 

 ‐

Logging,

 

high

 

alarm

 

for

 

TEMP

 

 

Yellow

 

single

 

flash

 

every

 

60

 

sec.

 

 ‐ 

RHT10

 

memory

 

full

 

 

Download

 

data

 

 

*

 

To

 

save

 

power,

 

the

 

RHT10’s

 

LED

 

flashing

 

cycle

 

can

 

be

 

changed

 

to

 

20s

 

or

 

30s

 

via

 

the

 

supplied

 

software.

 

**

 

To

 

save

 

power,

 

alarm

 

LEDs

 

for

 

temperature

 

can

 

be

 

disabled

 

via

 

the

 

supplied

 

software.

 

 

When

 

the

 

battery

 

is

 

low,

 

all

 

operations

 

will

 

be

 

disabled

 

automatically.

   

NOTE:

 

Logging

 

automatically

 

stops

 

when

 

the

 

battery

 

weakens

 

(logged

 

data

 

will

 

be

 

retained).

   

The

 

supplied

 

software

 

is

 

required

 

to

 

restart

 

logging

 

and

 

to

 

download

 

logged

 

data.

  

 

When

 

both

 

temperature

 

and

 

relative

 

humidity

 

readings

 

exceed

 

alarm

 

level

 

simultaneously,

 

LED

 

status

 

indication

 

alternates

 

every

 

other

 

cycle.

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for RHT10

Page 1: ...USER GUIDE Humidity Temperature Datalogger Model RHT10 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...upplied with a long life lithium battery which can typically allow logging for one year This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Features Memory for 32 000 readings 16 000 temperature and 16 000 humidity ...

Page 3: ...iption 1 Protective cover 2 USB connector to PC port 3 Start button 4 RH and Temperature sensors 5 Alarm LED red yellow 6 Record LED green 7 Mounting clip www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 4: ...automatically open and provide on screen prompts open and browse the CD ROM drive then find and double click on the SETUP EXE file included on the program disk Follow the on screen prompts to complete the installation Software Install Run SETUP up exe and follow the defaults to install he RTH10 software USB Driver Install 1 Open the root folder of the RHT10 2 Open the folder Driver DriverUSBXPRESS...

Page 5: ...aph icon on your desktop to launch the program The opening screen will appear as shown below Click on Connect to open the main screen Click on About to view the version number Click on View File to open an existing file Click on Quit to close the program www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 6: ...Setup window will appear as shown below descriptions for each field in the Setup window are listed directly below the illustration The CURRENT TIME field will automatically synchronize with the PC date and time setting The MANUAL and INSTANT select buttons allow the user to start data logging immediately when the Setup window is exited INSTANT or at a later time MANUAL The LOGGER NAME field allows...

Page 7: ...cting a specified number of sample points Always ensure that the remaining charge in the battery is sufficient to last the complete duration of your logging exercise When in doubt we recommend that you always install a fresh battery before logging critical data If INSTANT was selected in the SETUP window the RHT10 begins logging at the instant the SETUP button is pressed If MANUAL was selected the...

Page 8: ...gs If the readings are successfully transferred the VIEW screen and the SAVE screen both shown below will appear In the SAVE screen name the file and save it to a convenient location The data is saved as an rec file for use in this program only At a later time the user can select SAVE AS and save the data as an Excel Text or Bitmap file explained in next section In the screen below press VIEW to s...

Page 9: ...lick and drag a box around any data area to magnify the selected area 2 Click on the zoom magnifier icon tool on the menu bar 3 Select VIEW ALL or ZOOM OUT from the VIEW pull down menu In the example graph above the Temperature is represented by the solid red line the lines are known as traces the RH and Dew Point are represented by the solid yellow and green lines respectively The low and high al...

Page 10: ... the FILE pull down menu The data can be saved in the following formats TEXT FILE txt EXCEL FILE xls BITMAP FILE bmp To open an existing data file for viewing on the data graph window click on the FILE OPEN icon on the menu bar 3rd from left or select FILE OPEN from the FILE pull down menu When prompted select a rec file saved earlier FILE PRINT To print a data graph window to a line or network pr...

Page 11: ...part number RHT10 SW Note that the standard RHT10 software must be un installed before the optional RHT10 SW software can be installed To view GPP data click on the VIEW menu heading and scroll down to the SHOW TRACES tab Ensure that the GPP line is checked If checked the graph will display GPP data If unchecked the graph will not show GPP data www GlobalTestSupply com Find Quality Products Online...

Page 12: ...ce battery Record Alarm Yellow single flash every 10 sec Logging low alarm for TEMP Yellow double flash every 10 sec Logging high alarm for TEMP Yellow single flash every 60 sec RHT10 memory full Download data To save power the RHT10 s LED flashing cycle can be changed to 20s or 30s via the supplied software To save power alarm LEDs for temperature can be disabled via the supplied software When th...

Page 13: ...erature Overall Range 40 to 158o F 40 to 70o C Accuracy 25o C 40 to 100 RH 4 0o F 2o C Grains per pound 1120 gpp 160g kg max Available only with optional RHT10 SW software Logging rate Selectable sampling interval From 2 seconds up to 24 hours Operating temperature 31 to 176o F 35 to 80o C Battery type 3 6V Lithium 1 2 AA SAFT LS14250 Tadiran TL 5101 or equivalent Battery life 1 year typ depending...

Page 14: ... Before replacing the battery remove the datalogger from the PC Follow diagrammatic steps 1 through 4 below NOTE Leaving the RHT10 plugged into the PC USB port longer than necessary will cause some of the battery capacity to be lost WARNING Handle lithium batteries carefully observe warnings on battery casing Dispose of in accordance with local regulations Safety Please dispose of batteries respon...

Page 15: ... Inc specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Cust...