Specifications 

Display  

60 x 50 mm (2.4 x 2.0”) LCD  

Measurements 

Temperature, Relative Humidity, and Barometric Pressure  

Memory Card 

SD memory card, 1 GB to 16 GB 

Datalogger Sampling Time 

5/10/30/60/120/300/600 seconds or Automatic 

Temperature Compensation 

Automatic  

Display update rate 

Approx. 1 second 

 

Data Output 

RS 232 Serial Interface  

Operating Temperature

 

0 to 50°C (32 to 122°F) 

Operating Humidity 

Less than 90% RH 

Power Supply 

Six (6) ‘AAA’ Alkaline or heavy duty 1.5 V batteries or 
9V AC adaptor 

Battery life 

Dependent on sample rate, for new alkaline batteries and 60 second 
sampling time, > one month is typical (fast sample rates will 
significantly reduce battery life) 

Weight 

282 g (0.62 lbs.) 

Dimension 

132 x 80 x 32mm (5.2 x 3.1 x 1.3”) 

 

 

Range Resolution 

Accuracy 

(of 

reading) 

0.0 to 50.0 °C 

0.1°C 

± 0.8°C 

Temperature

 

32.0 to 122.0°F 

0.1°F 

± 1.5°F  

70 to 90% 

0.1% 

± (4% of rdg + 1% RH) 

Relative Humidity

 

10 to 70% 

0.1% 

± 4% RH 

10.0 to 1000.0 hPa 

0.1 

± 2 hPa 

1000.1 to 1100.0 hPa 

0.1 

± 3 hPa 

7.5 to 825.0 mmHg 

0.1 

± 1.5 mmHg 

Barometric Pressure 

0.29 to 32.48 inHg 

0.01 

± 0.1 inHg 

 
Note: Above specification tests under the environment RF Field Strength less than 3 V/M & frequency 
less than 30 MHz only. 

 

 

All EU users are legally bound by the Battery Ordinance to return all used batteries to 
community collection points or wherever batteries / accumulators are sold. 
Disposal in household trash or refuse is prohibited. 

Disposal: 

Follow the valid legal stipulations in respect of the disposal of the device at the 

end of its lifecycle 

 

Other Battery Safety Reminders 

 

Never dispose of batteries in a fire. Batteries may explode or leak.

 

 

Never mix battery types. Always install new batteries of the same type.

 

 

 
 

Copyright 

©

 2013 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in whole or in part in any form 

ISO-9001 Certified 

www.extech.com 

 

Summary of Contents for SD700

Page 1: ...USER GUIDE Barometric Pressure Humidity and Temperature Datalogger Model SD700 ...

Page 2: ...d and calibrated and with proper use will provide years of reliable service Please visit the Extech Instruments website www extech com to check for the latest version of this User Guide Extech Instruments is an ISO 9001 certified company Features LCD simultaneously displays Temperature Pressure and Humidity data Datalogger date time stamps and stores readings on an SD card in Excel format for easy...

Page 3: ...e Display 3 Pressure Display 4 LOG ENTER button 5 SET button 6 AC adaptor socket 7 Sensors 8 TIME button 9 button 10 Reset button 11 RS 232 output 12 SD memory card socket Note Battery Compartment and Tilt Stand are located on the back of the meter 10 11 12 1 2 3 4 5 6 7 8 9 ...

Page 4: ...ion of this manual to correctly format the card The internal clock must be set to the correct time See the advanced features section of this manual to set the clock The default data structure uses a decimal point as the numeric decimal indicator See the advanced features section to change this to a comma If the SD memory card is not installed EMPTY will appear in the display Displayed error messag...

Page 5: ...0 000 3 After 30 000 columns a new file HBA01002 xls is created This is repeated every 30 000 columns until HBA01099 XLS At this point a new folder HBA02 is created and the process is repeated HBA10 is the final folder Transferring Data to a PC 1 Remove the memory card from the datalogger and plug it into the SD card slot on the PC 2 Launch Excel and open the data file on the memory card from with...

Page 6: ...e Enter button to store the value and to step through the various fields 3 SP t Set the sample rate Press the button to select the desired sample rate and press Enter to store the selection The selections are 5 10 30 60 120 300 600 seconds and AUTO In AUTO the data will be stored every time there is a value change of 1 RH OR 1 C 4 bEEP Set the beeper ON or OFF Press the button to select ON or OFF ...

Page 7: ... Temperature 32 0 to 122 0 F 0 1 F 1 5 F 70 to 90 0 1 4 of rdg 1 RH Relative Humidity 10 to 70 0 1 4 RH 10 0 to 1000 0 hPa 0 1 2 hPa 1000 1 to 1100 0 hPa 0 1 3 hPa 7 5 to 825 0 mmHg 0 1 1 5 mmHg Barometric Pressure 0 29 to 32 48 inHg 0 01 0 1 inHg Note Above specification tests under the environment RF Field Strength less than 3 V M frequency less than 30 MHz only All EU users are legally bound by...

Reviews: