Introduction 

Congratulations on your purchase of the Extech SDL350 Hot Wire Thermo-Anemometer Datalogger. 
This meter displays and stores air velocity and temperature readings. Temperature readings from the 
thermometer built into the probe or from an externally connected type K or J thermocouple 
temperature probe can be displayed and recorded. Data is stored on an SD card for transfer to a PC. 
This instrument is shipped fully tested and calibrated and, with proper use, will provide years of reliable 
service. Please visit the Extech Instruments website (

www.extech.com

) to check for the latest version 

of this User Guide. Extech Instruments is an ISO-9001 certified company. 

 

 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the 
manual for further information. 
 

 

Description 

METER AND HOT WIRE PROBE 

1. Thermocouple 

input 

2. 

Hot Wire input plug 

3. 

Display for air velocity and air flow readings 

4. 

Units of measure 

5. HOLD 

Backlight   key 

6. MAX-MIN 

key 

7. 

SET and Clock 

  key 

8. 

PC interface jack 

9. Reset 

key 

10.  Power Adaptor jack 
11.  SD card slot 
12.  ENTER and LOG key 
13. Down 

arrow and FUNCTION key 

14. Up 

 arrow and UNIT key 

15. Power 

ON-OFF  key 

16.  Temperature reading with units of measure 
17.  Hot Wire probe cable 
18.  Telescoping probe handle 
19.  Protective cover (sensors underneath) 
20.  Colored dot must face air flow 

HOT WIRE PROBE TOP (detail) 

1. 

Air stream must face into colored dot 

2. 

Air velocity sensor 

3. 

Sliding protective cover OPEN position  

4. 

Sliding protective cover CLOSED position 

5. Temperature 

sensor 

NOTES:

 

Battery compartment, tilt stand, and tripod mount are located on the rear of the instrument. 
Items 8, 9, and 10 are located behind the snap-off compartment cover on right side of meter. 

Summary of Contents for SDL350

Page 1: ...Hot Wire 5 USER MANUAL Hot Wire Thermo Anemometer with Datalogger Model SDL350...

Page 2: ...nt to another symbol or terminal indicates the user must refer to the manual for further information Description METER AND HOT WIRE PROBE 1 Thermocouple input 2 Hot Wire input plug 3 Display for air v...

Page 3: ...isplay the air velocity measurement upper display area and the air temperature lower display area Changing the Air Velocity Unit of Measure This meter offers five 5 units of measure selections for air...

Page 4: ...eading will hold and the HOLD display icon will switch on Press the HOLD key again to release the display and exit the Data Hold mode returning the meter to the normal operating mode MAX MIN Readings...

Page 5: ...he user SD Card Information Insert an SD card from 1G size up to 16G into the SD card slot at the bottom of the meter With regard to orientation the card should be inserted with the front of the card...

Page 6: ...der is created on the card and named AHB01 Up to 99 spreadsheet documents each with 30 000 readings can be stored in this folder 7 When datalogging begins a new spreadsheet document named AHB01001 xls...

Page 7: ...e Setup mode if no key is pressed in 7 seconds while in the Setup mode 5 The available Setup parameters are listed below Additional detailed information is provided below this list dAtE Set the clock...

Page 8: ...setting 4 Press and hold the SET key for at least 1 5 seconds to exit to the normal operation mode or simply wait 7 seconds for the meter to automatically switch to the normal operating mode Numerical...

Page 9: ...ducts 3 14 R2 is used for circular ducts Note that the value must be set in square feet or square meters therefore if the measurement is made in square inches the area value must be converted to squa...

Page 10: ...e sampling rate to 0 Memory Card SD memory card 1G to 16GB size Temperature Compensation Automatic temperature compensation for the Anemometer function and the type K J thermometer function Data Hold...

Page 11: ...1 F 2 0 C 3 6 F Air Flow CFM CMM Volume Measurement unit Range Resolution CMM m3 minute 0 to 54 000 CMM 0 001 to 1 CMM CFM ft3 minute 0 to 1 907 000 CFM 0 001 to 100 CFM Air Temperature via Type K or...

Reviews: