7
SDL710-en-GB_V1.0 12/16
Manual
Datalogging
In
the
manual
mode
the
user
presses
the
LOG
button
to
manually
log
a
reading
onto
the
SD
card.
1.
Set
the
sampling
rate
to
‘0’
seconds
as
described
in
the
Setup
Mode
section.
2.
Press
and
hold
the
LOG
button
for
at
least
1.5
seconds
and
the
DATALOGGER
icon
will
appear
on
the
LCD;
the
lower
portion
of
the
display
will
show
p
‐
n
(
n
=
memory
position
number
1
‐
99).
Note
that
if
PSI
is
set
as
the
unit
of
measure
it
appears
as
P51
(where
a
‘5’
is
used
as
an
‘S’)
in
the
same
area
of
the
LCD
where
memory
locations
are
shown.
This
can
be
disorienting
at
first.
3.
Momentarily
press
the
LOG
button
to
store
a
reading.
The
DATALOGGER
icon
will
flash
and
the
beeper
will
sound
(if
set
to
ON)
each
time
a
data
point
is
stored.
4.
Use
the
▲
and
▼
buttons
to
select
one
of
the
99
data
memory
positions
in
which
to
record.
5.
To
exit
the
manual
datalogging
mode,
press
and
hold
the
LOG
button
for
at
least
1.5
seconds.
The
DATALOGGER
icon
will
switch
off.
Automatic
Datalogging
In
automatic
datalogging
mode
the
meter
takes
and
stores
a
reading
at
a
user
‐
specified
sampling
rate
onto
an
SD
memory
card.
The
meter
defaults
to
a
sampling
rate
of
two
seconds.
To
change
the
sampling
rate,
refer
to
the
Setup
Mode
section
(the
sampling
rate
cannot
be
‘0’
for
automatic
datalogging):
1.
Select
the
sampling
rate
in
the
Setup
Mode
to
a
value
other
than
zero.
2.
Press
and
hold
the
LOG
button
for
at
least
1.5
seconds.
The
meter
will
flash
the
DATALOGGER
icon
at
the
selected
sampling
rate
indicating
that
readings
are
now
being
automatically
recorded
to
the
SD
card.
3.
If
a
card
is
not
inserted
or
if
the
card
is
defective,
the
meter
will
display
EMPTY
and
exit
the
DATALOGGER
mode.
In
this
case,
switch
the
meter
OFF
and
try
again
with
a
valid
SD
card.
4.
Pause
the
datalogger
by
pressing
the
LOG
button
momentarily.
The
DATALOGGER
icon
will
stop
flashing
and
the
sample
rate
will
display
for
a
short
time.
To
resume
logging
simply
press
the
LOG
button
again
momentarily.
5.
To
terminate
the
datalogging
session
press
and
hold
the
LOG
button
for
at
least
1.5
seconds.
6.
When
an
SD
card
is
used
for
the
first
time
a
folder
is
created
on
the
card
and
named
PMA01
.
Up
to
99
spreadsheet
documents
(each
with
30,000
readings)
can
be
stored
in
this
folder.
7.
When
datalogging
begins
a
new
spreadsheet
document
named
PMA01001.xls
is
created
on
the
SD
card
in
the
PMA01
folder.
The
data
recorded
will
be
placed
in
the
PMA01001.xls
document
until
30,000
readings
are
reached.
8.
If
the
measurement
session
exceeds
30,000
readings,
a
new
document
will
be
created
(PMA01002.xls)
where
another
30,000
readings
can
be
stored.
This
method
continues
for
up
to
99
documents,
after
which
another
folder
is
created
(PMA02)
where
another
99
spreadsheet
documents
can
be
stored.
This
process
continues
in
this
same
fashion
with
folders
PMA03
through
PMA10
(last
allowable
folder).
www.calcert.com
sales@calcert.com
1.888.610.7664
0
5
10
15
20
25
30