Operation

 

 

AC/DC

 

Magnetic

 

Field

 

Measurement

 

Switch

 

the

 

meter

 

ON

 

by

 

pressing

 

and

 

holding

 

the

 

POWER

 

button

 

for

 

at

 

least

 

two

 

seconds.

 

Press

 

and

 

hold

 

the

 

FUNCTION

 

button

 

to

 

select

 

either

 

DC

 

or

 

AC

 

magnetic

 

field

 

measurement.

 

Press

 

and

 

hold

 

the

 

RANGE

 

button

 

until

 

the

 

desired

 

range

 

(1

 

or

 

2)

 

is

 

selected.

 

Select

 

the

 

desired

 

unit

 

of

 

measure

 

(mT

 

or

 

G).

 

 

For

 

DC

 

magnetic

 

field

 

measurements,

 

the

 

display

 

will

 

show

 

either

 

the

 

N

 

or

 

S

 

indicator.

 

For

 

the

 

North

 

Pole,

 

the

 

N

 

indicator

 

will

 

be

 

shown.

 

Similarly,

 

for

 

the

 

South

 

Pole,

 

the

 

S

 

indicator

 

will

 

be

 

shown.

 

For

 

AC

 

magnetic

 

field

 

measurements,

 

the

 

display

 

will

 

show

 

the

 

AC

 

indicator.

 

The

 

display

 

will

 

not

 

show

 

the

 

N

 

or

 

S

 

indicator.

 

 

Contact

 

and

 

press

 

the

 

testing

 

material

 

to

 

the

 

probe

 

head

 

(see

 

Fig

 

1).

 

The

 

display

 

will

 

show

 

the

 

magnetic

 

field

 

value

 

along

 

with

 

the

 

measurement

 

unit

 

(mT

 

or

 

G).

 

 

Figure

 

1

 

Note

:

 

When

 

the

 

meter

 

is

 

powered

 

ON,

 

the

 

display

 

may

 

show

 

a

 

non

zero

 

value;

 

this

 

is

 

because

 

of

 

environmental

 

interference.

 

Before

 

taking

 

a

 

measurement,

 

set

 

the

 

probe

 

at

 

the

 

optimum

 

position.

 

To

 

Zero

 

the

 

display,

 

press

 

and

 

hold

  

the

 

 

and

 

 

buttons

 

until

 

the

 

display

 

shows

 

the

 

0

 

value

 

and

 

the

 

display

 

flashes

 

the

 

ZERO

 

indicator.

 

The

 

meter

 

is

 

now

 

zeroed.

 

 

 

 

Data

 

Hold

 

During

 

the

 

measurements,

 

press

 

the

 

HOLD

 

button

 

to

 

freeze

 

a

 

displayed

 

reading.

 

The

 

measured

 

value

 

will

 

be

 

held

 

and

 

the

 

LCD

 

will

 

display

 

the

 

HOLD

 

symbol.

 

Press

 

the

 

HOLD

 

button

 

again

 

to

 

release

 

the

 

data

 

hold

 

function.

 

 

Summary of Contents for SDL900

Page 1: ...USER GUIDE AC DC Magnetic Meter Model SDL900...

Page 2: ...al material electrical laboratory and field use DC and AC magnetic field measurements North and South pole indicator Automatic temperature compensation Zero button for DC magnetic function Separate pr...

Page 3: ...ton 4 POWER Button 5 SET Button 6 RANGE Up Arrow Button 7 FUNCTION Down Arrow Button 8 ENTER LOG Button 9 MAX MIN Button 10 RS 232 Output Terminal Side 11 Reset Button Side 12 DC 9V Power Adapter Inpu...

Page 4: ...the display will show the AC indicator The display will not show the N or S indicator Contact and press the testing material to the probe head see Fig 1 The display will show the magnetic field value...

Page 5: ...Set sampling time from 0 3600 seconds POFF Auto power OFF management BEEP Set beeper ON OFF DEC Set SD card Decimal character comma for metric or decimal for imperial SD F Format the SD memory card UN...

Page 6: ...ies the decimal function is represented by the comma symbol Use the and buttons to select USA or EURO Selecting USA enables the decimal point format Selecting EURO enables the comma format Press the E...

Page 7: ...MPTY and exit the DATALOGGER mode In this case switch the meter OFF and try again with a valid SD card 4 Pause the datalogger by pressing the LOG button momentarily The DATALOGGER icon will stop flash...

Page 8: ...ill flash each time a data point is stored Use the and buttons to select one of the 99 data memory positions in which to record To exit the manual datalogging mode press and hold the LOG button for at...

Page 9: ...battery compartment and screws where they will not be damaged or lost Replace the six 6 1 5V AA batteries observing polarity Replace the battery compartment cover with the two 2 Phillips screws Note...

Page 10: ...e 2 15 000 G x 1 G Accuracy at 23 5 C DC 5 rdg 10 dgt AC 5 rdg 20 dgt Frequency Response AC Measurement 50 Hz 60 Hz Sensor Hall Sensor Datalogger Sampling Time and Setting Range Auto 1 second to 3600...

Page 11: ...d the backlight is OFF Approx 35 mA DC If the backlight is on the power consumption increases by approximately 3 mA Weight meter and probe 303g 10 7 oz Dimensions Main Instrument 182 x 73 x 47 5 mm 7...

Reviews: