background image

EXTECH

 

INSTRUMENTS

 

5

                                                      

SDL900

en

GB_V1.4

   

5/15

 

Data

 

Record

 

(Maximum

 

and

 

Minimum

 

Reading)

 

Press

 

the

 

REC

 

button

 

to

 

start

 

the

 

data

 

record

 

function.

 

The

 

LCD

 

will

 

display

 

a

 

REC

 

symbol.

 

Press

 

the

 

REC

 

button

 

again,

 

and

 

the

 

REC

 

MAX

 

symbol

 

along

 

with

 

the

 

maximum

 

reading

 

value

 

will

 

be

 

displayed.

 

Press

 

the

 

REC

 

button

 

again

 

to

 

display

 

the

 

minimum

 

value.

 

The

 

LCD

 

will

 

also

 

show

 

the

 

REC

 

MIN

 

symbols.

 

To

 

exit

 

this

 

mode,

 

press

 

and

 

hold

 

the

 

REC

 

button

 

for

 

two

 

seconds.

 

The

 

meter

 

will

 

return

 

to

 

the

 

normal

 

operating

 

mode.

 

 

Note:

 

When

 

making

 

DC

 

magnetic

 

field

 

measurements

 

in

 

the

 

RECORD

 

mode,

 

the

 

meter

 

cannot

 

be

 

changed

 

from

 

North

 

pole

 

to

 

South

 

pole,

 

or

 

vice

 

versa.

   

 

Set

 

Mode

 

Press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

two

 

seconds

 

to

 

enter

 

the

 

Set

 

Mode.

 

Momentarily

 

pressing

 

the

 

SET

 

button

 

will

 

cycle

 

throughout

 

the

 

seven

 

functions.

 

They

 

are

 

(in

 

order):

 

 

DATE………

Set

 

clock

 

(Year/Month/Date,

 

Hour/Minute/Second)

 

SP

T……….

Set

 

sampling

 

time

 

(from

 

0

 

~

 

3600

 

seconds)

 

POFF…

……Auto

 

power

 

OFF

 

management

 

BEEP……...

Set

 

beeper

 

ON/OFF

 

DEC…

……..Set

 

SD

 

card

 

Decimal

 

character

 

(comma

 

for

 

metric

 

or

 

decimal

 

for

 

imperial)

 

SD

F……….

Format

 

the

 

SD

 

memory

 

card

 

UNIT…

…….Select

 

the

 

magnetic

 

field

 

units

 

(mT:

 

milli

 

Tesla

 

or

 

G:

 

Gauss)

 

 

Note:

 

Press

 

and

 

hold

 

the

 

SET

 

button

 

for

 

two

 

seconds

 

when

 

in

 

the

 

Set

 

Mode

 

to

 

exit.

 

 

Set

 

the

 

Clock

 

Time

 

and

 

Date

 

When

 

the

 

LCD

 

displays

 

DATE

,

 

press

 

the

 

ENTER

 

button.

 

Use

 

the

 

 

and

 

 

buttons

 

to

 

adjust

 

the

 

value

 

(starting

 

with

 

the

 

current

 

YEAR).

 

After

 

the

 

desired

 

value

 

is

 

set,

 

press

 

the

 

ENTER

 

button

 

to

 

step

 

to

 

the

 

next

 

item.

 

After

 

all

 

six

 

parameters

 

are

 

set,

 

press

 

the

 

ENTER

 

button

 

to

 

save

 

the

 

settings.

 

 

Note:

 

The

 

SDL900

 

internal

 

battery

 

allows

 

the

 

internal

 

clock

 

to

 

run

 

precisely,

 

even

 

after

 

it

 

is

 

switched

 

OFF

 

(as

 

long

 

as

 

the

 

battery

 

is

 

fresh).

 

 

Set

 

Sampling

 

Time

 

When

 

the

 

LCD

 

displays

 

SP

T

,

 

press

 

the

 

ENTER

 

button.

 

Use

 

the

 

 

and

 

 

buttons

 

to

 

adjust

 

the

 

sampling

 

time

 

(rate

 

of

 

datalogging)

 

to

 

0,

 

1,

 

2,

 

5,

 

10,

 

30,

 

60,

 

120,

 

300,

 

600,

 

1800,

 

or

 

3600

 

seconds.

 

After

 

the

 

desired

 

sampling

 

time

 

is

 

selected,

 

press

 

the

 

ENTER

 

button

 

to

 

save

 

the

 

setting.

 

Summary of Contents for SDL900

Page 1: ...USER GUIDE AC DC Magnetic Meter Model SDL900...

Page 2: ...al material electrical laboratory and field use DC and AC magnetic field measurements North and South pole indicator Automatic temperature compensation Zero button for DC magnetic function Separate pr...

Page 3: ...ton 4 POWER Button 5 SET Button 6 RANGE Up Arrow Button 7 FUNCTION Down Arrow Button 8 ENTER LOG Button 9 MAX MIN Button 10 RS 232 Output Terminal Side 11 Reset Button Side 12 DC 9V Power Adapter Inpu...

Page 4: ...the display will show the AC indicator The display will not show the N or S indicator Contact and press the testing material to the probe head see Fig 1 The display will show the magnetic field value...

Page 5: ...Set sampling time from 0 3600 seconds POFF Auto power OFF management BEEP Set beeper ON OFF DEC Set SD card Decimal character comma for metric or decimal for imperial SD F Format the SD memory card UN...

Page 6: ...ies the decimal function is represented by the comma symbol Use the and buttons to select USA or EURO Selecting USA enables the decimal point format Selecting EURO enables the comma format Press the E...

Page 7: ...MPTY and exit the DATALOGGER mode In this case switch the meter OFF and try again with a valid SD card 4 Pause the datalogger by pressing the LOG button momentarily The DATALOGGER icon will stop flash...

Page 8: ...ill flash each time a data point is stored Use the and buttons to select one of the 99 data memory positions in which to record To exit the manual datalogging mode press and hold the LOG button for at...

Page 9: ...battery compartment and screws where they will not be damaged or lost Replace the six 6 1 5V AA batteries observing polarity Replace the battery compartment cover with the two 2 Phillips screws Note...

Page 10: ...e 2 15 000 G x 1 G Accuracy at 23 5 C DC 5 rdg 10 dgt AC 5 rdg 20 dgt Frequency Response AC Measurement 50 Hz 60 Hz Sensor Hall Sensor Datalogger Sampling Time and Setting Range Auto 1 second to 3600...

Page 11: ...d the backlight is OFF Approx 35 mA DC If the backlight is on the power consumption increases by approximately 3 mA Weight meter and probe 303g 10 7 oz Dimensions Main Instrument 182 x 73 x 47 5 mm 7...

Reviews: