Chapter 5 – Recipe Setup
User Manual
47
Vortex
®
Precedence
Rev 3.6
Model Gain
Touch the box to toggle between High, Medium,
& Low gain settings. Start with the High setting
and reduce if erratic motion occurs during
rotation. Normally this setting will always be set
to High.
Upper Valve
Touch the box to toggle between Vacuum &
Pressure. This selects the appropriate valves in
the machine for vacuum/pressure at the upper
tool.
Pressure/Vacuum Sensor
(
Optional feature) Toggle this box to enable or
disable the spindle pressure/vacuum sensor, if
installed. Note this will only be used if
Vacuum/Pressure Load or Vac Pickup/Prs Pickup
Load Modes are used (see next page).
Servo Accel
Touch the box and enter the servo acceleration
value as a percent of maximum. Start with a
high acceleration to achieve weld speed quickly.
Decrease the acceleration if the tool has a high
rotational inertia and erratic motion or faults are
occurring when rotation begins.
Servo Decel
Touch the box and enter the servo deceleration
value as a percent of maximum. A high
deceleration is good because it will reduce the
possibility of weld cooling and solidification
during deceleration. However, high deceleration
may reduce final positioning accuracy in tools
with high rotational inertia values. Reduce the
deceleration if final positioning accuracy is poor
or if erratic motion is observed at the end of the
cycle.
Part Present Input Usage
Touch the checkboxes to select which inputs are
used for part presence sensing on this tool. If a
box is checked the machine will require that
input to be on (PNP – active high) before the
cycle will start. The part present sensors must
be wired into the tool IO connector as described
in Chapter 3.
Summary of Contents for VORTEX PRECEDENCE G1
Page 66: ...Chapter 6 Operation User Manual 60 Vortex Precedence Rev 3 6 Sequence of Operations Flowchart ...
Page 69: ...Chapter 6 Operation User Manual 63 Vortex Precedence Rev 3 6 ...
Page 88: ...Chapter 8 Troubleshooting User Manual 82 Vortex Precedence Rev 3 6 Servo Drive Alarms ...
Page 89: ...Chapter 8 Troubleshooting User Manual 83 Vortex Precedence Rev 3 6 ...
Page 90: ...Chapter 8 Troubleshooting User Manual 84 Vortex Precedence Rev 3 6 ...
Page 91: ...Chapter 8 Troubleshooting User Manual 85 Vortex Precedence Rev 3 6 Servo Drive Warnings ...
Page 104: ...651 Case Karsten Drive Zeeland MI 49464 1 800 324 6205 www extolinc com ...