Chapter 5 – Recipe Setup
User Manual
50
Vortex
®
Precedence
Rev 3.6
Trigger Window
The Trigger Window specifies the tolerance of
the trigger position. See above for an
explanation of the trigger function. The trigger
window only applies in Static Start Mode or Vac
Pickup Load Mode.
Max Collapse
The Max Collapse is only used in Dynamic Start
Mode with Vacuum or Detent Load Modes. The
Max Collapse specifies the maximum amount of
allowable travel after the trigger position. If the
head travels farther a fault will be displayed.
c. Weld Process
Touch the Weld Process area of the process
flowchart (Figure 5-5) and specify the weld
mode, weld mode parameter(s), start delay,
weld force, and weld speed. Note: Only the
selected weld mode controls the welding
process. Un-selected modes can be ignored.
Weld Mode
1. Revolutions
Beginning from the specified start angle, the
upper tool will rotate the number of
revolutions specified and then continue
rotating in the same direction until it reaches
the final angle.
Revolutions
Enter the number of revolutions to spin from
the start angle.
Orientation
Select whether final orientation positioning
will be enabled for this weld process. Note:
Orientation is automatically turned on in
Revolutions Mode.
Final Angle
Enter the angular orientation of the desired
final position of the upper tool. The upper
tool will rotate the specified number of full
revolutions and then continue in the same
direction until it reaches the final angle (see
examples).
Figure 5-5 Setup-Parameters, Weld Process
Summary of Contents for VORTEX PRECEDENCE G1
Page 66: ...Chapter 6 Operation User Manual 60 Vortex Precedence Rev 3 6 Sequence of Operations Flowchart ...
Page 69: ...Chapter 6 Operation User Manual 63 Vortex Precedence Rev 3 6 ...
Page 88: ...Chapter 8 Troubleshooting User Manual 82 Vortex Precedence Rev 3 6 Servo Drive Alarms ...
Page 89: ...Chapter 8 Troubleshooting User Manual 83 Vortex Precedence Rev 3 6 ...
Page 90: ...Chapter 8 Troubleshooting User Manual 84 Vortex Precedence Rev 3 6 ...
Page 91: ...Chapter 8 Troubleshooting User Manual 85 Vortex Precedence Rev 3 6 Servo Drive Warnings ...
Page 104: ...651 Case Karsten Drive Zeeland MI 49464 1 800 324 6205 www extolinc com ...