Chapter 5 – Recipe Setup
User Manual
52
Vortex
®
Precedence
Rev 3.6
Total
Specify the total distance that the head is to
travel. Note: the actual final position will be
greater because of the welding that
continues during deceleration and additional
compression that may occur during cooling.
The amount is dependent on the part
diameter and joint design.
Start Delay
This parameter only applies to Static Start Mode
and Vac Pickup Load Mode. Specify the amount
of time to dwell at the trigger position before
rotation begins. This can be used to allow force
to build at the weld joint before welding.
Weld Force
Specify the force used during the weld process.
The machine automatically compensates for the
weight of the spindle and tool then adjusts the
air pressure in the cylinder to achieve the
specified force.
Weld Speed
Specify the rotational speed of the tool. Enter a
positive value for clockwise rotation. Enter a
negative value for counterclockwise rotation.
Note: Actual top speed may be less if other
parameters do not allow enough time to reach
full speed.
d. Hold Settings
Touch the Hold area of the process flowchart
(Figure 5-8) and specify the hold force and hold
time.
Hold Force
Specify the force used during the hold time. The
machine changes to this force immediately after
the weld process is complete. The machine
automatically compensates for the weight of the
spindle and tool then adjusts the air pressure in
the cylinder to achieve the specified force.
Hold Time
Specify the amount of time to hold the parts
together at the specified hold force after the
Figure 5-8 Setup-Parameters, Hold Settings
Summary of Contents for VORTEX PRECEDENCE G1
Page 66: ...Chapter 6 Operation User Manual 60 Vortex Precedence Rev 3 6 Sequence of Operations Flowchart ...
Page 69: ...Chapter 6 Operation User Manual 63 Vortex Precedence Rev 3 6 ...
Page 88: ...Chapter 8 Troubleshooting User Manual 82 Vortex Precedence Rev 3 6 Servo Drive Alarms ...
Page 89: ...Chapter 8 Troubleshooting User Manual 83 Vortex Precedence Rev 3 6 ...
Page 90: ...Chapter 8 Troubleshooting User Manual 84 Vortex Precedence Rev 3 6 ...
Page 91: ...Chapter 8 Troubleshooting User Manual 85 Vortex Precedence Rev 3 6 Servo Drive Warnings ...
Page 104: ...651 Case Karsten Drive Zeeland MI 49464 1 800 324 6205 www extolinc com ...