The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the eAsY seTUp function, it is possible to change the calibration of the volumetric weight by increasing or decreasing
the preset values.
in the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value, which is 0.
if there is an excessive deposit on the burn pot, access the eAsY seTUp program and lower the value to “- 1”; then wait until the next day and
if there is no improvement, lower it again down to a limit value of “- 3”.
instead, if it is necessary to increase the calibration of the volumetric weight of the pellet, change the factory value from “0” to “+ 1, + 2, + 3”
as required.
EXCESSIvE PELLET DEPOSIT IN BURN POT
NORMAL OPERATION
MINIMUM PELLET DEPOSIT IN BURN POT
-3
-2
-1
0
+1
+2
+3
ThirD
DecreAse
rAnge iF The
FirsT TWo Are
insUFFicienT
seconD
DecreAse
rAnge iF
The FirsT is
insUFFicienT
FirsT DecreAse
rAnge (TesT
For 1 DAY)
opTimAL FAcTorY
vALUe
FirsT increAse
rAnge
seconD
increAse
rAnge iF
The FirsT is
insUFFicienT
ThirD increAse
rAnge iF The
FirsT TWo Are
insUFFicienT
conTroLs proceDUre
press key 6.
press key 3 until
EASY SETUP
appears and confirm by pressing key 6.
Use keys 4 -5 to set the range.
press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
N.B.: If THESE ADjUSTmENTS DO NOT SOLvE THE PROBLEm Of PELLET DEPOSITS IN THE BURN POT, PLEASE CONTACT YOUR
LOCAL SERvICE CENTRE.
vENTILATION
The menu allows you to enable and adjust the speed (-2, -1, 0, +1, +2) of the front fan.
enABLing conTroLs proceDUre
press key 6.
press 3 until
vENTILATION
appears and confirm by pressing 6.
confirm
ENABLINg
by pressing 6.
Use keys 4 -5 to enable (
ON
) or disable (
OFF
) and confirm by pressing 6.
press 1 to return to the previous menus to the initial state.
speeD ADjUsTmenT conTroLs proceDUre
press key 6.
press 3 until
vENTILATION
appears and confirm by pressing 6.
Keep pressing key 3 until
SPEED
appears and confirm by pressing key 6.
Use keys 4 -5 to adjust the speed (-2, -1, 0, +1, +2) and confirm by pressing 6.
press 1 to return to the previous menus to the initial state.
seT ThermosTAT conTroLs proceDUre
press key 6.
press 3 until
vENTILATION
appears and confirm by pressing key 6.
Keep pressing 3 until
SET THERMOSTAT
appears and confirm by pressing 6.
Use keys 4 5 to adjust the room temperature (7°c - 37°c) and confirm by pressing 6.
press 1 to return to the previous menus to the initial state.