no flaMe
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “
easy seTup
”).
DepR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
no
iGniTion
The pellet hopper is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “
easy seTup
”).
Check the procedures described in the “Ignition” chapter.
Check bulb thermostats (see chapter on Resetting)
no
iGniTion
BlaCk ouT
No current during the ignition phase.
Take the stove to OFF conditions using key 1 and repeat the procedure
described in the "Ignition" chapter.
CoMManD auGeR
alaRM
Abnormal pellet loading.
Contact after-sales centre
auGeR BloCkeD
Abnormal operation of pellet motor
Contact after-sales centre
MaX eleCTRiCal CuR-
RenT
The automatic cleaning of the burn pot is
blocked. Burn pot dirty or clogged or door not
closed properly
Check that the door is closed properly
Check that the burn pot is free and clean
If the problem persists, contact the after-sales centre.
Min H20 pRessuRe
alaRM
The system pressure read by the pressure switch
is too low.
Possible air in the system; bleed the system. Possible lack of water or leaks
due to anomalies in some system component.
If the problem persists, contact the service centre.
MaX H20 pRessuRe
alaRM
Air in the system
Inadequate circulation
Possible air in the system; bleed the system. Lack of adequate circulation.
Lack of or inadequate safety zone.
The water in the stove has exceeded 95°C. Possible pump anomaly.
If the problem persists, restore operations must be performed by an
authorised technician.
H2o pRoBe
H2O probe fault
Contact after-sales centre
* DHW pRoBe
Fault in
DHW probe
.
Contact after-sales centre
* BuffeR Tank pRoBe
Fault in
Buffer tank probe
.
Contact after-sales centre
TRapDooR BloCkeD
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty or clogged
The door is not closed correctly.
Check that the door closes correctly. Check that the burn pot is clear and
clean.
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre.
BloCkeD pWM
alaRM
The pump has stopped permanently
Pump blocked. Electronic module damaged
Contact after-sales centre
HoT pWM alaRM
The pump is operating but not with good
performance. Undervoltage 160-194V.
Pump in circuit breaker protection mode.
Contact after-sales centre
sToppeD pWM
alaRM
The pump has stopped but is still operational.
Undervoltage < 160V Overvoltage.
Unexpected external flow.
Contact after-sales centre
sToppeD 2 pWM
alaRM
The pump has stopped but is still operational.
Problem in a component different to the pump.
Debris in installation.
Positioning in high temperature.
Contact after-sales centre
floW pWM alaRM
Pump blocked.
Liquid with high density.
Pipe obstructed.
Presence of air in the system.
Contact after-sales centre
pWM inTeRfaCe
alaRM
iPWM output interface damaged, in short
circuit or not connected
Contact after-sales centre