TA
TA
ENGLISH
ReaRming
If a fuse blows, it is recommended to contact a qualified technician
to check the cause.
fuse
If there is no power supply to the stove, check the state of the fuse
located in the box between the stove switch and the power cable
connection.
ta supplementaRy theRmostat (optional)
The appliance is able to control the room temperature through a supplementary thermostat (optional).
After ignition (by pressing key 1 or through the chrono mode), the stove will work to reach the temperature set on the thermostat, displaying
woRk
(
closed contact
). The room probe incorporated into the handheld device is automatically ignored,
installation must Be peRfoRmeD By qualifieD staff anD/oR the manufactuReR's afteR-sales
technicians.
Z1 moDe
set to
"on":
Set the desired temperature on the
set
Zone Z1
(from
07 - 40°C
)
.
•
Until the desired temperature is reached the ducting motor will follow the stove settings.
•
When the temperature set on
set zone z1
is reached, the ducting motor will switch to
the 1st speed.
Z1 moDe
on
eCo:
Set the desired temperature on the
set
Zone Z1
(from
07 - 40°C
)
.
•
Until the desired temperature is reached the ducting motor will follow the stove settings.
•
When the temperature set on
set zone z1
is reached, the ducting motor will turn off, and
then turn on again when required.
Same SettingS for Z2 ducting
with pRoBe (ntC 10K)
Remove the bridge on Z1 and attach the ntC probe in the room where you wish to control the temperature through Z1 ducting.
two operating modes:
TO InSTALL AnD ACTIvATE:
A mechanical or digital thermostat is required.
Remove the plug from the socket.
Using the figure to the side as a reference, connect the two thermostat cables (clean contact - no
220 v!) onto the relative terminals located on the back of the appliance, one red and the other
black.
Connect the power to the stove again.
Press the key (
OK
), and set temperature is set to LOW-TA.
The stove is now correctly configured.
It will work by checking the supplementary external thermostat, based on the TA function (see TA