ENGLISH
dISplay
The "dISplAY" menu allows:
regulation of display contrast
Activation/deactivation of backlight.
enabling/disabling of acoustic signal.
Set the timer to turn off the display backlight.
Set the timer to turn off the display (sleep mode).
SettInGS
SeT clocK
xx:xx - dd/mm/yy
date and time setting
lAnguAge
ita-ing-fra-ted-spa
language setting
dISplAY
display regulation
STAnd-BY
on/off
enables or disables the STAnd-BY FuncTIon
delTA T
oFF - 0.5 - 5.5°c
delTA T regulation
SettInGS
SeT clocK
xx:xx - dd/mm/yy
date and time setting
lAnguAge
ita-ing-fra-ted-spa
language setting
dISplAY
display regulation
STAnd-BY
on/off
enables or disables the STAnd-BY FuncTIon
delTA T
oFF - 0.5 - 5.5°c
delTA T on/oFF regulation
Stand-By wIth dIGItal thermOStat (Standard)
StBy FUnctIOn Set tO On
When the STBY function is active (on), if the room temperature exceeds the set value plus
delTa T off
, the stove will switch off after a pre-set
(default) delay period, and STAnd-BY will be displayed on the screen.
When the room temperature is lower than the set value less
delTa T off
and the stove has cooled, it will start to work again at the set power,
and work will be displayed on the screen.
StBy FUnctIOn Set tO OFF
(FAcTorY deFAulT SeTTIng)
When the Stby function is not activated (oFF), if the stove reaches the set room temperature, it will switch to the minimum power level,
modulating and displaying modulation on the screen. When the room temperature is lower than the set value, the stove will start to work
again at the set power, and work will be displayed on the screen.
Stand-By wIth SUpplementary thermOStat (OptIOnal)
StBy FUnctIOn Set tO OFF
(FAcTorY deFAulT SeTTIng)
When the STBY function is not activated (oFF), if the stove reaches the room temperature set on the supplementary thermostat (open contact),
it will switch to the minimum power level and display
mOdUlatIOn
on the screen. When the room temperature is lower than the set value on
the supplementary thermostat (closed contact), the stove will start to work again at the set power, and
wOrk
will be displayed on the screen.
StBy FUnctIOn Set tO On
If the Stby function is activated (on), when the room temperature set on the supplementary thermostat is reached (open contact), the stove
will switch off after a pre-set (default) delay period, and
Stand-By
will be displayed on the screen.
When the room temperature is lower than the value set on the supplementary thermostat (closed contact), the stove will start to work again
at the set power, and
wOrk
will be displayed on the screen
J
thIS FUnctIOn IS nOt recOmmended FOr rOOmS wIth Scarce thermal InSUlatIOn Or where there may
Be Sharp FlUctUatIOnS In temperatUre: dOOrS Or wIndOwS cOnStantly Opened.
Stand-By
The Stby function is used in the event the stove needs to immediately switch off once temperature is reached.
By factory default this function is disabled (oFF).