28
ENGLISH
if the power Cord is damaged, it must be replaCed by the after-sales serviCe or by a similarly
Qualified person, so as to avoid all risks.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE
WEBSITE:
WWW.LANORDICA-EXTRAFLAME.COM
routine maintenanCe performed by Qualified teChniCians
routine maintenance must be performed at least once a year.
Using pellets as solid fuel, the generator requires annual routine maintenance, which must be performed by a
qualified technician, using
only original spare parts.
Failure to comply with this may jeopardise the safety of the appliance and invalidate the warranty.
Respecting the cleaning frequencies reserved for the user described in the use and maintenance manual ensures correct combustion over
time, avoiding any anomalies and/or malfunctions which may require more complex interventions by the technician. Requests for routine
maintenance interventions are not included in the product warranty.
seals: pellet hopper lid, door, ash drawer and burn pot
The seals ensure that the stove is airtight and they guarantee the proper operation of the same.
They must be regularly checked: if they are found to be worn or damaged, they must be replaced immediately.
These operations must be performed by a qualified technician.
ConneCtion to the flue
Vacuum and clean the pipe that leads to the flue yearly or any time that it is necessary. If there are any horizontal sections, the residues must
be removed before they obstruct the fumes passage.
putting out of serviCe (end of season)
At the end of each season, before turning the stove off, it is advisable to empty the pellet hopper out completely and vacuum any pellet and
dust residues.
It is also advisable to disconnect the generator from the electrical power supply and, for greater safety especially in the presence of
children, remove the power cord
.
Routine maintenance must be performed at least once a year.
PARTS/FREQUENCY
EVERY DAY
EVERY 7 DAYS
EVERY 30 DAYS
EVERY YEAR
BURN POT
X
UPPER DEFLECTOR
X
COMBUSTION CHAMBER
X
TUBE BUNDLE
X
EXTRACTABLE ASH DRAWER 1
X
EXTRACTABLE ASH DRAWER 2
X
T-SHAPED FITTING/ SMOkE DUCT
X