7.0 CONTROL PANEL
POWER BUTTON
ON/OFF
DisPlay
TO aCCEss
THE MENU
TEMPERaTURE
sETTiNG
DisPLAy iCONs kEy
indicates the receipt of the radio signal
On = during radio communication
Off = no radio communication
Fixed on = serial input disabled
indicates the status of the additional thermostat input (GND - i3)
indicates exhaust motor operation.
Off = exhaust motor disabled
On = exhaust motor active
Flashing = breakdown
indicates ducted motor operation
Off = Motor disabled
On = Motor active
Flashing = the motor is running at minimum and in modulation
mode (additional input open)
1
indicates convection fan operation (where applicable)
Off = not working
On = working
Flashing = motor at minimum
indicates the activation of the F1 function (future set-up)
Off = function disabled
On = function active
indicates auger motor operation
Off = pellet feed motor disabled
On = pellet feed motor active
indicates weekly programming functioning
indicator on = weekly programming active
indicator off = weekly programming disabled
indicates the compensation function (Reserved to qualified
technician)
Off = the function is disabled
On = the function is active
indicates the appliance modulation
On = the appliance is working at the set power
Flashing = the power at which the appliance is working is different
to the power set, the appliance is modulating (for various reasons)
indicates the contact of the external additional thermostat
Contact closed:
the contact of the external additional
thermostat is closed and the
STBY
function is disabled
Contact open:
the contact of the external additional
thermostat is open and the
STBY
function is disabled
Flashing with closed
contact:
the contact of the external additional
thermostat is closed and the
STBY
function is active
Flashing with open
contact:
the contact of the external additional
thermostat is open and the
STBY
function is active
indicates the presence of an alarm.
On: indicates the presence of an alarm
Off: indicates the absence of alarms
indicates the room temperature status
Off = the T° read by the probe is above the set temperature
On = the T° read by the probe is below the set temperature
Hopper probe
Off = probe ok
On = broken probe (short circuit or open)
Flashing = modulation due to hopper.
POWER lEVEls
(HEaT)
lED aCTiVaTiON
liGHTs
Summary of Contents for Vicenza V3.4
Page 14: ...SECURING kit FIGURE 2 14 W415 1598 06 01 16 ...
Page 46: ...47 18 0 NOTES W415 1598 06 01 16 ...
Page 47: ...48 W415 1598 06 01 16 ...
Page 62: ...14 W415 1598 06 01 16 KIT DE FIXATION FIGURE 2 ...
Page 68: ...20 W415 1598 06 01 16 6 0 assemblage de panneau en céramique inférieur 2 1 ...