26
W415-1598 / 06.01.16
10.0 OPERATiON AND LOGiC
iGNiTiON
Once the points listed previously have been checked, press key 1 for three seconds to ignite the appliance. The
iGNiTiON
phase lasts
15 minutes then once the control temperature has been reached, the appliance switches to the
STaRT-uP
phase. (No adjustments can
be made during the
STaRT-uP
phase).
sTART-uP
During the
STaRT-uP
phase, the appliance stabilizes combustion, increasing power (burn rate) gradually and starting ventilation, in
order to switch into WORk phase.
wORk
During the
WORk
phase, the appliance reaches the set power and works to reach the set room temperature.
ThERMOsTAT sETTiNG ADjusTMENT
The room temperature setting can be set using buttons 4 and 5, between 44°F and 104°F (7°C to 40°C) or from
lOW to HOT
.
LOw - hOT
if the temperature setting is on
lOW
(set below the 44°F (7°C ) threshold) the appliance will always function at minimum.
if the setting is on
HOT
set above the 104°F (40°C) threshold, the appliance will not modulate. The appliance will continue to operate
but only at the set power.
POwER sETTiNG hEAT
The power setting features 5 operating levels set using button 3 (decrease) and 2 (increase).
Power 1 = minimum level - Power 5 = maximum level.
wORk wiTh ROOM PROBE (sTANDARD)
The appliance controls the room temperature via a probe fitted on the appliance.
Once the the set temperature has been reached, it will automatically go to minimum or switch off activating the
STaNdBY
function,
reducing pellet consumption to a minimum.
By default the
STBY
function is always set on
OFF
(light
on).
For its activation and logic, see "sTaNDBy" section.
BuRN POT CLEANiNG
During the
WORk
phase, the appliance has an internal counter which cleans the burn pot after a set amount of time.
BuRN POT CLEANiNG
will be shown on the display. it will bring the appliance to a lower power level and will increase the exhaust
motor for a programmed amount of time.
When the
BuRN POT CLEANiNG
stage is finished, the appliance will return to the previous wORk phase power setting..
swiTCh-OFF
Press key 1 for three seconds.
When the operation has been performed, the appliance automatically enters the
SWiTcH-OFF
phase, stopping the supply of pellets.
The exhaust motor and the hot air ventilation motor will remain on until the temperature of the appliance has dropped below
the factory parameters.
REiGNiTiON
The appliance can only be reignited if the flue gas temperature has lowered and the preset timer has been reset to zero. if the preset
time is interrupted by sending a command, the timer wil restart.
DO NOT usE ANy iNFLAMMABLE LiquiDs FOR iGNiTiON. NEvER usE GAsOLiNE, GAsOLiNE-TyPE LANTERN
FuEL, kEROsENE, ChARCOAL LiGhTER FLuiD, OR siMiLAR LiquiDs TO sTART OR 'FREshEN uP' A FiRE iN This
APPLiANCE. kEEP ALL suCh LiquiDs OR siMiLAR LiquiDs AwAy FROM ThE APPLiANCE whiLE iT is iN usE.
DO NOT ALLOw ThE BAG OF PELLETs TO COME iNTO CONTACT wiTh ThE hOT APPLiANCE DuRiNG ThE FiLLiNG
PhAsE.
iN ThE EvENT OF CONTiNuOus FAiLED iGNiTiON, CONTACT AN AuThORizED TEChNiCiAN.
DO NOT OvERFiRE ThE APPLiANCE. NEvER FEED PELLETs ThROuGh ThE GLAss viEwiNG DOOR. AN
"OvERFiRE" CONDiTiON COuLD OCCuR iF MORE PELLETs ENTER ThE FiREBOX ThAN whAT ThE FEED TuBE CAN
DELivER. PELLETs MusT ONLy BE BuRNED wiThiN ThE BuRN POT.
10.1 PiLOT MODE
When the appliance modulates to minimum power (P-1) and achieves set temperature, PilOT MODE will activate.
The front fan will switch off and the appliance will heat by radiation.
sET COMMissiONiNG sETTiNGs PRiOR TO OPERaTiON.
Summary of Contents for Vicenza V3.4
Page 14: ...SECURING kit FIGURE 2 14 W415 1598 06 01 16 ...
Page 46: ...47 18 0 NOTES W415 1598 06 01 16 ...
Page 47: ...48 W415 1598 06 01 16 ...
Page 62: ...14 W415 1598 06 01 16 KIT DE FIXATION FIGURE 2 ...
Page 68: ...20 W415 1598 06 01 16 6 0 assemblage de panneau en céramique inférieur 2 1 ...