6
W415-1598 / 06.01.16
approximate Maximum Heating Capacity (in square feet)*
800-2,000 sq. ft
.
burn Rate
1.38 - 4.05 lbs/h (0.63 - 1.84 kg/h)
** global btu/h
11,840 - 34,564 btu/h (3.47 - 10.13 kw)
Maximum burn time on low burn**
21h
efficiency (overall)
85.1%
Heat Output Range
10,000 - 28,000 btu/hr
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. it is also affected
by the fuel size, quality, and moisture level.
** small pellets will increase or decrease the stated burn rates and burn times. differences of plus or minus 20%
depending on fuel quality may occur.
For best performance, operate the appliance on low. Operating on low burn achieves the best efficiency.
2.2.1 HEATING SPECIFICATIONS
2.3 GENERAL INSTRUCTIONS
WARNING
all wirinG should be done bY a Qualified electrician and shall be in coMpliance with local codes. in
the absence of local codes, use the current csa c22.1
canadian electric code (in canada) or the ansi/nfpa no. 70 national electric code in the united states.
do not connect this appliance to a chiMneY flue servinG another appliance. do not connect to anY air
distribution duct or sYsteM.
provide adeQuate clearance for servicinG and operatinG the appliance.
provide adeQuate ventilation.
never obstruct the front openinG of the appliance.
obJects placed in front of the appliance Must be Kept a MiniMuM of 48” (1200mm) froM the front face of
the appliance.
thank you for purchasing a Vicenza Pellet appliance. this appliance is designed for use with Pelletized wood Only.
Please read this entire manual before installation and use of this pellet fuel-burning room appliance. Failure to follow these instructions
could result in property damage, bodily injury or even death. Keep this manual handy for future reference.
this Pellet appliance, when installed, must be electrically grounded in accordance with the local codes, or in the absence of local
codes, use the current Csa C22.1 Canadian electrical Code in Canada or the ansi/nFPa 70 national electrical Code in the United states.
this appliance will not operate using natural draft or without a power source for the blower systems and fuel feed system. this
appliance needs periodic inspection and repair for proper operation. it is against federal regulations to operate this appliance in a
manner inconsistent with operating instructions in this manual.
the protective wrap on plated parts is best removed when the assembly is at room temperature but this can be improved if the assembly
is warmed, using a hair dryer or similar heat source. we recommend using a mild soap and water solution and a soft nonabrasive cloth
to remove any residue left on the plated parts from the protective wrap before exposing them to the heat from the appliance.
if the appliance is installed directly on carpeting, vinyl tile or combustible material than wood flooring, the appliance shall be installed
on a non-combustible floor protector extending the full width and depth.
this appliance has a manufacturer-set minimum low burn rate that must not be altered. it is against federal regulations to alter this
setting or otherwise operate this appliance in a manner inconsistent with operating instructions in this manual.
the correct use of the appliance and periodic maintenance will minimize smoke and visible emissions.
do not alter or tamper with any parts or settings of this appliance. any alterations or tampering may result in the immediate void of
the warranty.
Summary of Contents for Vicenza V3.4
Page 14: ...SECURING kit FIGURE 2 14 W415 1598 06 01 16 ...
Page 46: ...47 18 0 NOTES W415 1598 06 01 16 ...
Page 47: ...48 W415 1598 06 01 16 ...
Page 62: ...14 W415 1598 06 01 16 KIT DE FIXATION FIGURE 2 ...
Page 68: ...20 W415 1598 06 01 16 6 0 assemblage de panneau en céramique inférieur 2 1 ...