Extreme Networks
LRM/MACsec Adapter
Quick Reference
Part no. 10965
Hardware Components
shows the ports, LEDs, and connections on the LRM/MACsec
Adapter.
Figure 1 LRM/MACsec Adapter Converter: Front Panel
Installation Site Requirements
The installation site must meet the following requirements:
•
Located within 50 cm (19.7 in) of the host switch to which it will be
attached
•
A temperature between 0°C (32°F) and 45°C (113°F), with
fluctuations of less than 10°C (18°F) per hour
Handling the Equipment
To minimize the risk of ESD damage, follow appropriate ESD
procedures when unpacking and handling the LRM/MACsec Adapter.
These include unpacking the equipment in an ESD safe environment
and wearing appropriate ESD protective gear, such as ESD-safe
footwear and ESD wrist straps where appropriate.
Unpack the equipment as follows:
1
Remove the packing material protecting the equipment.
2
Remove the tape seal on the non-conductive bag to remove the
equipment.
3 Perform a visual inspection of the equipment for any signs of
physical damage. Contact Extreme Networks if there are any signs
of damage. See
for more information on contacting
Extreme Networks.
Installing the LRM/MACsec Adapter
You can install the LRM/MACsec Adapter converter in a standard
equipment rack, in any of three ways shown in
Figure 2 Mounting Options for the LRM/MACsec Adapter
Mounting Option 1: Horizontal
To mount the LRM/MACsec Adapter vertically on the rack
1
Using two small M4x6.5mm screws (included), attach the bracket to
the holes in one side of the adapter so that the mounting ear
extends away from the adapter.
shows the bracket attached to the adapter.
Figure 3 Bracket Attached to Adapter for Horizontal Mounting
2 Using two rack mounting screws (not included) attach the
mounting ear to the rack.
The adapter ports should face toward the front.
3 Connect the adapter to the switch, following the instructions in
“Connecting the LRM/MACsec Adapter to the Host Switch”
.
Mounting Option 2: In the 5-Slot Bracket
To mount the LRM/MACsec Adapter in the 5-slot bracket:
1
Using standard rack mounting screws (not included), secure the
bracket to the rack.
2 Set the adapter in one of the bracket slots.
3 Secure the adapter to the bracket using one of the M4x6.5mm
screws provided with the bracket.
4 Mount up to four additional LRM/MACsec Adapter units on the
bracket, as described in steps
5 Connect the adapters to the switch, following the instructions in
“Connecting the LRM/MACsec Adapter to the Host Switch”
Mounting Option 3: Vertical
To mount the LRM/MACsec Adapter vertically on the rack:
1
Using two rack mounting screws (not included), attach the vertical
mounting bracket to the rack so that the mounting ear extends
outward from the front of the rack.
2 Using two small M4x6.5mm screws (included), attach the bracket to
the holes in the bottom of the adapter.
The adapter ports can face upward or downward as needed.
3 Connect the adapter to the switch, following the instructions in
“Connecting the LRM/MACsec Adapter to the Host Switch”
Connecting the LRM/MACsec Adapter to
the Host Switch
After mounting the LRM/MACsec Adapter in the rack, attach it to the
host switch by doing the following:
1
Insert one of the 50 cm SFP cables, included with the adapter, into
Host Port1 on the front of the LRM/MACsec Adapter.
This SFP cable is provided especially for use with the
LRM/MACsec Adapter
. It is not a standard SFP cable.
2 Insert the other end of the cable into an SFP port on the switch.
3 Repeat steps
to connect Host Port2 to the switch. Both
Host Port1 and Host Port2 must be connected to the host switch.
The LRM/MACsec Adapter receives power through its connection to
the host switch’s SFP port. Optionally, in addition to the power it
receives from the switch, it can receive power through the USB
connector on the front panel.
When the LRM/MACsec Adapter is connected to the host switch,
verify that the adapter’s power LED turns on. If the power LED does
not turn on, recheck the connection between the adapter and the
power source(s).
Specifications
LRM/MACsec Adapter
Part number
: 10965
Unpackaged Weight
: 300 g (0.66 lb)
Dimensions
:
3.00 cm (1.18 in) H
7.60 cm (2.99 in) W
12.35 cm (4.86 in) L
Operating Temperature
:
0°C to 40°C (32°F to 104°F) when used with Tunable DWDM SFP+,
ER SFP+, ZR SFP+, and Bidirectional 120 km SFP optics modules
0°C to 45°C (32°F to 113°F) when used with all other optics modules
Storage Temperature
: -40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity
: 10% to 95% (non-condensing)
Five-Slot Bracket
Part number
: 10966
Unpackaged Weight
: 487 g (1.07 lb)
Dimensions
:
4.32 cm (1.70 in) H
5.60 cm (2.20 in) L
48.26 cm (19.00 in) W
Electrical Hazard:
Only qualified personnel should perform installation
procedures.
Risques d’électrocution:
Seul un personnel qualifié doit effectuer les
procédures d'installation.
1
USB connector
3
SFP+ ports (host)
2
SFP+ ports (link)
Caution:
Failure to follow proper ESD handling procedures may result in
damage to the equipment.
1
Horizontal Mount
3
Vertical Mount
2
5-Slot Bracket (part no. 10966)