GE and Console Connections
The access points have two GE (Ethernet) ports and a Console port. During administration and
maintenance through the GE or Console port, the access points must still have a power connection
through an Ethernet PoE cable.
For information about the location of the GE and console ports, see
.
Console Cap Assembly
About This Task
The GE ports, console port, and vent on all outdoor access points must be torqued properly to ensure
proper protection of access points against water intrusion. The access points come with a console port
tie that must be torqued.
Procedure
1. Tighten the M25 console cap to a torque of 8.7 in-lbs.
Note
If a torque wrench is not available, tighten the console cap by hand. Use an open end
wrench to tighten the cap between 1/8
th
to 1/4
th
turn.
ExtremeWireless™ AP460i/e Access Points
37