background image

7

Extreme Networks Data Sheet: 

BlackDiamond X8

*Per-port power is based on ATIS calculation per Lippis test report.

Operating Specifications

•  Operating Temperature Range: 0° C to 40° C 

(32° F to 104° F)

•  Operating Humidity: 10% to 95% relative 

humidity, non-condensing

•  Operational Altitude: up to 2000m (6561 

feet)

•  Operational Shock: 30 m/s

2

 (3g), 11ms, 60 

Shocks

•  Operational Random Vibration: 3-500MHz @ 

1.5g rms

Packaging and Storage 

Specifications

•  Storage/Transportation Temperature: -40° C 

to 70° C (-40° F to 158° F)

•  Storage and Transportation Humidity: 10% to 

93% RH

•  Packaged Shock (Half Sine):

 

< 50 kg 180 m/s

2

 (10 g), 6 ms, 600 shocks, 

modules

 

> 50 kg 100 m/s

2

 (6 g), 11 ms, 600 shocks, 

chassis

•  Packaged Sine Vibration: 5-62 Hz @ Velocity 

5mm/s, 62-500 Hz @ 0.2G

•  Packaged Random Vibration: 5-20Hz @

ASD=1.0 & 20-200Hz @-3dB/octave

•  Packaged drop height

 

@ 39.5” <22 lb (10 kg) modules

 

@ 11.8” <110 lb (50 kg) chassis

Regulatory/Safety

North American Safety

•  cULus 60950-1:2007 2nd Ed., Listed Device 

(U.S.)

•  CSA 22.2#60950-1-03 1st Ed. 2006-07 

(Canada)

•  Complies with FCC 21CFR Chapter1, 

Subchapter J (U.S. Laser Safety)

•  CDRH Letter of Approval (U.S. FDA Approval)

European Safety

•  CB Scheme, IEC 60950-1:2005+National 

Deviations

•  EN 60825-1:2007 (Lasers Safety)
•  206/95/EC Low Voltage Directive

International Safety

•  GS Mark, EN 60950-1:2006+A11:2009+A1:200

+A12:2011

•  Taiwan CNS 14336-1(2010) (BSMI)
•  AS/NZX 60950-1 (Australia/New Zealand)

EMI/EMC Standards

North American EMC Standards

•  FCC CFR 47 part 15 Class A (U.S.)
•  ICES-003 Class A (Canada)

European EMC Standards

•  EN 55022:2010 Class A
•  EN 55024:2010 Class A
•  EN 55011:2009+A1:2011
•  EN 61000-3-2:2006+A2:2009 (Harmonics)
•  EN 61000-3-3:2008 (Flicker)
•  EN 61000-6-4:2007+A1:2011 (Emissions for 

Industrial, Scientific & Medical)

•  EN 61000-6-2:2005 (Immunity for Industrial, 

Scientific & Medical)

•  ETSI EN 300 386 v1.6.1 (2012-09) EMC 

Telecommunications

•  2004/108/EC EMC Directive

International EMC Certifications

•  CISPR 22:2010), Class A (International 

Emissions)

•  CISPR 24:2010 Class A (International 

Immunity)

•  IEC 61000-4-2:2008 Electrostatic Discharge, 

8kV Contact, 15kV Air, Criteria A

•  IEC 61000-4-3:2010 Radiated Immunity 

20V/m, Criteria A

•  IEC 61000-4-4:2012 Transient Burst, 1kV, 

Criteria A

•  IEC 61000-4-5 2005 Surge, 2kV, 4kV, 

Criteria A

•  IEC 61000-4-6:2008 Conducted Immunity, 

0.15-80MHz, 10V/m unmod. RMS, Criteria A

•  IEC 61000-4-11:2004 Power Dips & 

Interruptions, >30%, 25 periods, Criteria C

Country Specific

•  Japan Class A (VCCI)
•  Australia/New Zealand, RCM 
•  Taiwan EMC CNS 13438(95) Class A, Safety 

CNS 14336-1(2010) (BSMI)

•  Brazil (ANATEL)
•  China, complex equipment exemption 

(CCC)

•  Mexico (via NRTL Listing)
•  South Korea KN22, KN24 (KCC)

Telecommunication Standards

•  ETSI EN 300 386 v1.6.1 (2012-09) EMC 

Telecommunications)

•  ETSI EN 300 019 (Environmental for 

Telecommunications)

IEEE 802.3 Media Access 

Standards 

•  IEEE 802.3z 1000BASE-X
•  IEEE 802.3ae 10GBASE-X
•  IEEE 802.3ba 40GBASE-X
•  IEEE 802.3ac VLAN Tag
•  IEEE 802.3ad Link Aggregation

Operational and 

Transportation Standards 

•  EN/ETSI 300 019-2-1 v2.1.2 – Class 1.2 Storage
•  EN/ETSI 300 019-2-2 v2.2.1 – Class 2.3 

Transportation

•  EN/ETSI 300 019-2-3 v2.2.2 – Class 3.1e 

Operational

•  EN/ETSI 300 753 v1.2.1 (2009-7) – Acoustic 

Noise

•  ASTM D3580 Random Vibration Unpackaged 

1.5G

Fan and Acoustic Noise

•  Sound pressure for comparison to legacy 

standards per ISO 7779:2010(E)

 

Low Speed: 60.3 dB(A) (LpA) 

 

Medium Speed: 66.0 dB(A) (LpA) 

 

High Speed: 82.3 dB(A) (LpA) 

•  Sound power per ISO 7779:2010(E), ISO 

3744:2010(E), ETSI/EN 300 753:2007(E)

 

Low Speed: 72.0 dB(A) (LWAm)

 

Medium Speed: 78.0 dB(A) (LWAm) 

 

High Speed: 94.4 dB(A) (LWAm) 

•  Declared sound power per 300 753 :2011-11) 

via ISO 9296:2010 &

 

Low Speed: 7.5 bels (LWAd)

 

Medium Speed: 8.1 bels (LWAd) 

 

High Speed: 9.7 bels (LWAd)

Warranty

•  Ltd. 1-year on Hardware
•  90-days on Software
•  For warranty details, visit 

www.extremenetworks.com/go/warranty

Power Specifications

Power Supply

•  Rated Inputs:

 

Low Range: 100-120VAC, 60/50 Hz, 13 A 
max each power supply

 

High Range: 200-240VAC , 60/50 Hz, 13 A 
max each power supply

•  Input Ranges:

 

Low Range: 90 -132VAC, 47 - 63 Hz

 

High Range: 185 - 264VAC, 47 - 63 Hz

•  Power supply input socket IEC 320 C20

•  Power cord input plug IEC 320 C19

•  Power cord-sets up to 2m (6.5ft) length 

require minimum 16 AWG (1.0 mm2) copper 
stranded wire 
Power cord-sets greater than 2m (6.5ft) 
length require minimum 14 AWG (1.25 mm2) 
copper stranded wire 
(The power supply cord-set wall plug must 
be appropriately rated and approved for the 
country of installation)

•  Efficiency 90% typical at full load

•  DC voltage output range: 47.5 to 48.5 Vdc

•  Nominal DC output:

 

Low Range: 48 Vdc , 25 A maximum each 
PSU

 

High Range: 48 Vdc , 50 A maximum each 
PSU

•  DC output power:

 

2500W @ high range for one PSU (See 
manual for more than one PS)

 

1250W @ low range for one PSU (See 
manual for more than one PS)

Power Consumption

•  Worst case power consumption and heat 

load (With 10Tbps SFM):

 

4,436 W at output of power supplies

 

4,929 W at input of power supplies

 

16,817 BTU/Hour total heat load

•  Worst case power consumption and thermal 

(With 20Tbps SFM):

 

6,532 W at output of power supplies

 

7,258 W at input of power supplies

 

24,764 BTU/Hour total heat load

•  Typical power consumption: *

 

5.6 W per 10GbE, 22.5 W per 40GbE

Summary of Contents for BlackDiamond X8 Series

Page 1: ...tes into 1 152 1GbE 2 304 10GbE 576 40GbE or 96 100GbE ports in a single rack or any combination of those The BlackDiamond X8 design leverages an orthogonal direct mating system between the interface and switch fabric modules eliminating the performance bottleneck of backplane or mid plane designs The BlackDiamond X8 offers up to 1 28Tbps capacity per slot with current switch fabric modules with a...

Page 2: ... single converged network With IEEE compliant lossless Ethernet implementation of Priority Flow Control PFC and Enhanced Transmission Selection ETS storage traffic can be prioritized queued and bandwidth guaranteed The BlackDiamond X8 also supports transit Fiber Channel over Ethernet FCoE for carrying converged fiber channel storage traffic In converged networks TRILL enables the building of flat ...

Page 3: ...in real time If any of these processes become unresponsive or stop running they can be automatically restarted without impacting other processes The BlackDiamond X8 supports a set of high availability features including In Service Software Upgrade ISSU future availability Multi Chassis Link Aggregation M LAG and Ethernet Automatic Protection Switching EAPS allowing the network to provide uninterru...

Page 4: ...amond X8 is connected to the core using 40GbE or 100GbE uplinks Features such as VEPA Port Isolation and TRILL can play key role in building a scalable flat network High Performance Compute Cluster In High Performance Computing and Super Computing where large numbers of compute nodes and storage need to be connected using low latency 10 and 40GbE the BlackDiamond X8 provides high density low laten...

Page 5: ...um 192 40GbE or 768 10GbE wire speed ports per system Supports 40GbE QSFP optics and cables Suited for high density low latency edge and core applications Enhanced Blank Panel Module 8 Blank Panels maximum Note Current shipping blank panel has screws instead of thumb levers Picture for future availability Required for the IO and Switch Fabric Modules to maintain proper airflow for cooling If not p...

Page 6: ...ntries 8K 512K with XL 4 094 VLANs Port Protocol IEEE 802 1Q 9216 Byte maximum packet size Jumbo Frame 384 link aggregation groups up to 64 members per trunk 2 048 ingress and 1 024 egress ACL rules per group of 24 10GbE or 6 40GbE ports 128K ingress and 1K egress ACL rules per group of 3 40Gb ports or 1 100GbE port with XL Ingress and egress bandwidth policing rate limiting per flow ACL Egress ba...

Page 7: ... A Safety CNS 14336 1 2010 BSMI Brazil ANATEL China complex equipment exemption CCC Mexico via NRTL Listing South Korea KN22 KN24 KCC Telecommunication Standards ETSI EN 300 386 v1 6 1 2012 09 EMC Telecommunications ETSI EN 300 019 Environmental for Telecommunications IEEE 802 3 Media Access Standards IEEE 802 3z 1000BASE X IEEE 802 3ae 10GBASE X IEEE 802 3ba 40GBASE X IEEE 802 3ac VLAN Tag IEEE 8...

Page 8: ...0GBASE X QSFP module for BlackDiamond X series chassis Up to 8 modules in the BDX8 chassis support up to 96 wirespeed 40GbE or 384 wirespeed 10GbE ports and work with either 2 56 or 5 12Tbps Fabric Modules Optics and cables are not included 48051 BDXA 40G24X 24 Port 40GBASE X QSFP module for BlackDiamond X series chassis Up to 8 modules in the BDX8 chassis support up to 192 wirespeed 40GbE or 768 ...

Page 9: ...ED IN THIS DATA SHEET INCLUDING ANY A WARRANTY OF MERCHANTABILITY OR B WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE WHETHER EXPRESS OR IMPLIED BY LAW COURSE OF DEALING COURSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Corporate and North America Phone 1 408 579 2800 Europe Middle East and Africa Phone 31 30 800 5100 Asia Pacific Phone 65 6586 9200 Latin America Phone 52 55 5557 6465 extremenetwork...

Reviews: