1554
ExtremeWare 7.5 Command Reference Guide
ESRP Commands
show elrp
show elrp {<vlan name> | detail}
Description
Displays ELRP information.
Syntax Description
Default
N/A.
Usage Guidelines
If you enter the
show elrp
command without a keyword, the command displays the:
•
Total number of clients registered with ELRP
•
ELRP packets transmitted
•
ELRP packets received
If you enter the
detail
keyword, more detailed status information for VLANs in the master and
pre-master states is displayed. If you enter a
vlan name
, the command displays ELRP information for
that specific VLAN.
The additional table output for the
detail
keyword or a specific VLAN name includes the following:
vlan name
Specifies an ESRP-enabled VLAN name.
detail
Specifies detail for each switch in the ESRP VLAN.
Client name
Displays the name of the ELRP client.
VLAN
Displays the name of the VLAN with ELRP enabled.
Interval
Displays the configured interval. An interval of 3 indicates that ELRP PDUs are transmitted
every 3 seconds.
Count
Lists the configured number of ELRP PDUs that are transmitted. The PDUs are transmitted at
the configured interval. This method of ELRP PDU transmission is used by ESRP in the
pre-master state. A count of 0 indicates continuous PDU transmission. If the Cyclic value is
Yes
, the count is always 0.
Cyclic
Indicates whether ELRP PDUs are being continuously sent. The column shows
Yes
for the
master VLAN because that VLAN is continuously sending ELRP PDUs for loop detection.
When a VLAN is in the pre-master state, it only sends three ELRP PDUs before changing to
master or slave. During this time the column shows
No
for that VLAN.
Pkts-Xmit
Displays the number of ELRP PDUs transmitted.
Pkts-Rcvd
Displays the number of ELRP PDUs received.
Summary of Contents for ExtremeWare 7.5
Page 402: ...402 ExtremeWare 7 5 Command Reference Guide VLAN Commands ...
Page 470: ...470 ExtremeWare 7 5 Command Reference Guide QoS Commands ...
Page 490: ...490 ExtremeWare 7 5 Command Reference Guide NAT Commands ...
Page 826: ...826 ExtremeWare 7 5 Command Reference Guide Commands for Status Monitoring and Statistics ...
Page 1090: ...1090 ExtremeWare 7 5 Command Reference Guide Security Commands ...
Page 1386: ...1386 ExtremeWare 7 5 Command Reference Guide Wireless Commands ...
Page 1436: ...1436 ExtremeWare 7 5 Command Reference Guide EAPS Commands ...
Page 1568: ...1568 ExtremeWare 7 5 Command Reference Guide ESRP Commands ...
Page 1844: ...1844 ExtremeWare 7 5 Command Reference Guide IGP Commands ...
Page 1930: ...1930 ExtremeWare 7 5 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2022: ...2022 ExtremeWare 7 5 Command Reference Guide IP Multicast Commands ...
Page 2066: ...2066 ExtremeWare 7 5 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2082: ...2082 ExtremeWare 7 5 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2094: ...2094 ExtremeWare 7 5 Command Reference Guide Remote Connect Commands ...
Page 2174: ...2174 ExtremeWare 7 5 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2372: ...2372 ExtremeWare 7 5 Command Reference Guide LLDP Commands ...
Page 2422: ...2422 ExtremeWare 7 5 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2528: ...2528 ExtremeWare 7 5 Command Reference Guide MPLS Commands BlackDiamond Switch Only ...