configure elrp-client periodic
ExtremeWare 7.7 Command Reference Guide
1503
configure elrp-client periodic
configure elrp-client periodic <vlan name> interval <seconds> ports
<port-mask> action [log | log-and-trap | trap]
Description
Starts periodic Extreme Loop Recovery Protocol (ELRP) packet transmission on the specified ports of
the VLAN using the specified interval.
Syntax Description
Default
None.
Usage Guidelines
This command starts periodic ELRP packet transmission on the specified ports of the VLAN using the
specified interval. If any of these transmitted packets is returned, indicating loopback detection, the
ELRP client can perform a configured action such as logging a message in the system log file and/or
sending a trap to the SNMP manager.
Use the
configure elrp-client one-shot
command to configure non-periodic, one-time
transmission of ELRP packets.
The ELRP client must be enabled globally in order for it to work on any VLANs. Use the
enable
elrp-client
command to globally enable the ELRP client.
The ELRP client can be disabled globally so that none of the ELRP VLAN configurations take effect. Use
the
disable elrp-client
command to globally disable the ELRP client.
Example
The following example configures a periodic request on VLAN
v1
, writes to the log file, and sends a
trap to the SNMP manager.
vlan name
Specifies a VLAN name.
interval <seconds>
Specifies the interval (in seconds) between consecutive packet transmissions.
Valid range for the interval is from 1 to 600 seconds.
ports <port-mask>
Specifies the set of VLAN ports for packet transmission.
action log
Specifies that a message should be logged in the system log file when ELRP
packets are received back indicating detection of network loop, or no packets
are received within the specified duration.
action trap
Specifies that a trap message should be sent to the SNMP manager when
ELRP packets are received back indicating detection of network loop, or no
packets are received within the specified duration.
action log-and-trap
Specifies that a message should be logged in the system log file and a trap
message should be sent to the SNMP manager when ELRP packets are
received back indicating detection of network loop, or no packets are received
within the specified duration.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...