330
ExtremeWare 7.7 Command Reference Guide
Commands for Configuring Slots and Ports on a Switch
show msm-failover
show msm-failover
Description
Displays hitless failover statistics.
NOTE
This command is available only on the BlackDiamond switches.
Syntax Description
This command has no arguments or variables.
Default
N/A
Usage Guidelines
None
Example
The following command displays MSM failover statistics:
show msm-failover
The output displays the following:
•
Current state of the MSM
•
Software image information (primary/secondary image, version)
•
Cause of the last failover
•
Failover configuration (link action, preserve state, slave configuration, timeout)
•
ESRP failover mode
•
Failover status for the supported subsystems (configuration, layer 2 hardware, layer 3 hardware, STP,
EAPS, ARP, ESRP)
Each of the supported subsystems display one of the following states:
—
disable—Hitless failover is disabled. This is also the initial state.
—
initial—Hitless failover is enabled, but the downloading of the subsystem state has not yet started
for a particular subsystem.
—
xfr—The subsystem’s state is in the process of being transferred to the slave. The state transfer
includes all of the state for that subsystem.
—
ready—The subsystem has received its state download. In the ready state, it may receive updates
to its internal states.
—
failed—The subsystem encountered a failure. To clear the failure, reboot the slave MSM.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...