configure log display
ExtremeWare 7.7 Command Reference Guide
681
configure log display
configure log display {<severity>}
Description
Configures the real-time log display.
Syntax Description
Default
If not specified, messages of all severities are displayed on the console display.
Usage Guidelines
You must enable the log display before messages are displayed on the log display. Use the
enable log
display
command to enable the log display. This allows you to configure the system to maintain a
running real-time display of log messages on the console.
Options for displaying the real-time log display include:
•
severity—Filters the log to display messages with the selected severity or higher (more critical).
Severities include critical, error, warning, info, notice, debug-summary, debug-verbose, and
debug-data.
In ExtremeWare 7.1.0, the ability to control logging to different targets was introduced. The new
command equivalent to
configure log display
is the following:
configure log target console-display severity <severity>
To display the current configuration of the log display, use the following command:
show log configuration target console-display
Example
The following command configures the system log to maintain a running real-time display of log
messages of critical severity:
configure log display critical
History
This command was first available in ExtremeWare 2.0.
The severity levels alert and emergency were deprecated to critical, and the levels debug-summary,
debug-verbose, and debug-data were added in ExtremeWare 7.1.0.
This command was added to the Summit “
e
” series of switches in ExtremeWare 7.1e.
severity
Specifies a message severity. Severities include critical, error, warning, notice, info, debug-summary,
debug-verbose, and debug-data.
Summary of Contents for ExtremeWare 7.7
Page 60: ...60 ExtremeWare 7 7 Command Reference Guide Contents ...
Page 72: ...72 ExtremeWare 7 7 Command Reference Guide Command Reference Overview ...
Page 404: ...404 ExtremeWare 7 7 Command Reference Guide VLAN Commands ...
Page 472: ...472 ExtremeWare 7 7 Command Reference Guide QoS Commands ...
Page 492: ...492 ExtremeWare 7 7 Command Reference Guide NAT Commands ...
Page 890: ...890 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1130: ...1130 ExtremeWare 7 7 Command Reference Guide Security Commands ...
Page 1164: ...1164 ExtremeWare 7 7 Command Reference Guide Configuration and Image Commands ...
Page 1436: ...1436 ExtremeWare 7 7 Command Reference Guide Wireless Commands ...
Page 1490: ...1490 ExtremeWare 7 7 Command Reference Guide EAPS Commands ...
Page 1576: ...1576 ExtremeWare 7 7 Command Reference Guide ESRP Commands ...
Page 1774: ...1774 ExtremeWare 7 7 Command Reference Guide IP Unicast Commands ...
Page 1914: ...1914 ExtremeWare 7 7 Command Reference Guide IGP Commands ...
Page 2000: ...2000 ExtremeWare 7 7 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2140: ...2140 ExtremeWare 7 7 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2156: ...2156 ExtremeWare 7 7 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2168: ...2168 ExtremeWare 7 7 Command Reference Guide Remote Connect Commands ...
Page 2346: ...2346 ExtremeWare 7 7 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2446: ...2446 ExtremeWare 7 7 Command Reference Guide LLDP Commands ...
Page 2496: ...2496 ExtremeWare 7 7 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2620: ...2620 ExtremeWare 7 7 Command Reference Guide Index of Commands ...