Install the Access Point on a Flat T-bar Using Main Mounting Bracket and
KT-135628-01 Adapter
Before You Begin
Ensure that the T-bar meets the following conditions before installing the main mounting bracket with
the KT-135628-01 adapter on a T-bar:
•
T-bar width can be either 9/16 in. (15 mm) or 15/16 in. (24 mm).
•
T-bar bottom must be flat all the way across.
•
T-bar must be structurally sound.
•
T-bar maximum base thickness must not exceed 0.055 in. (1.4 mm).
Due to manufacturing variation, some adapters can accommodate up to 0.060 in. (1.5 mm).
•
Ceiling tile may protrude up to 0.35 in. (8.89 mm) below the T-bar.
About This Task
If the ceiling tile is not flat and has a protrusion, use the main mounting bracket with the KT-135628-01
adapter. Attach the adapter to the main mounting bracket before attaching the bracket to a T-bar.
Procedure
1. Attach the T-bar adapter to the main mounting bracket by lining up the small bends on the adapter
with the long raised parts on the main bracket.
2. Pull up the KT-135628-01 adapter locking pin, and twist.
Ensure that the locking pin goes into the locking pin hole on the main bracket and locks in place.