background image

 
 

 

 

 

 
 

 

Installation in a Rack 

An ipe-2200ax appliance is to be installed in a rack. 

It is also possible to lay it on a table. Make sure it lays flat and it is stable. 

Warning

: whatever the method of installation used, do not obstruct the ventilation openings on the 

front and rear panels of the case. 

Choose a suitable location for the rack unit that will hold your appliance. It should be situated in a 
clean, dust-free and well ventilated area. Avoid areas where heat, electrical noise and 
electromagnetic fields are generated. You will also need it placed near a grounded power outlet. 

 

Preparing for Setup 

The box your chassis was shipped in should include two sets of rail assemblies, two rail mounting 
brackets and the mounting screws you will need to install the system into the rack. 

Please read this section in its entirety before you begin the installation procedure outlined in the 
sections that follow. 

Choosing a Setup Location 

 

Leave enough clearance in front of the rack to enable you to open the front door completely 

(~60 cm / 25 inches). 

 

Leave approximately 75 cm / 30 inches of clearance in the back of the rack to allow for sufficient 

airflow and ease in servicing. 

 

This product is for installation only in a Restricted Access Location (dedicated equipment rooms, 

service closets and similar environments). 

 

Rack Precautions 

 

Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the 

full weight of the rack resting on them. 

 

In single rack installation, stabilizers should be attached to the rack. 

 

In multiple rack installations, the racks should be coupled together. 

 

Always make sure the rack is stable before extending a component from the rack. 

 

You should extend only one component at a time. Extending two or more simultaneously may 

cause the rack to become unstable. 

 

Installation in a Rack 
 

ipe-2200ax-T and            
ipe-2200ax-F 

Summary of Contents for ipe-2200ax-T

Page 1: ...you begin the installation procedure outlined in the sections that follow Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely 60 cm 25 inches Leave approximately 75 cm 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing This product is for installation only in a Restricted Access Loca...

Page 2: ...on is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the appliance to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropri...

Page 3: ...ed before mounting onto the rack 1 Identify the left and right outer rails by examining the ends which bend outward Match the left front outer rail with the left rear outer rail and the same for the right rails 2 Align the round post in the rear rail B with the round hole at the end of the slot in the front rail A and slide the front section into the rear section ...

Page 4: ...2 Adjust the rail to reach the full depth of your rack 3 Align the square pegs on the rear end of the rail to the holes on the rack D and push the rail into the rack until the quick release bracket snaps into place securing the rail to the rack 4 Repeat the procedure for the other outer rail assembly Note the figure above is for illustrative purposes only Always install servers at the bottom of th...

Page 5: ...k www extremenetworks com 5 Note the figure above is for illustrative purposes only Always install servers at the bottom of the rack first Warning do not pick up the appliance with the front handles They are designed to pull the system from a rack only ...

Page 6: ... without notice Trademarks Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in this document are the property of their respective owners and may be trademarks or registered trademarks of their respective companies owners For additional info...

Reviews: