Table 126: Green Ethernet EEE Interface History Fields
Field
Description
Interface
Select the interface with the green mode information to view or configure.
Sample No.
A unique number that identifies the sample.
Age
The amount of time that has passed since the sample was recorded.
% Time in LPI since last sample The percentage of time the interface has spent in LPI mode since the last sample
was taken.
% Time in LPI since last reset
The percentage of time the interface has spent in LPI mode since the last time
the EEE statistics were cleared.
Configuring and Viewing Device Slot Information
The pages in the Slot folder provide information about the cards installed in the slots on the switch. The
physical location of the slots depends on the hardware on which 200 Series software is running. From
the Configuration page, you can also manually configure information about cards on some platforms.
Slot Card Configuration
Use the Card Configuration page to view information about the cards installed in a switch. On some
platforms, you can manually configure information about slots.
To access the page, click
System
>
Slot
>
Configuration
in the navigation menu.
lists the fields that display when the slot contains a card.
Table 127: Slot Configuration Fields
Field
Description
Slot
Identifies the slot number.
Status
Whether the slot is empty or full.
Administrative State
Whether the slot is administratively enabled or disabled. For some devices, you
can change the Administrative State when you add or edit slot information.
Power State
Whether the device is providing power to the slot. For some devices, you can
change the Power State when you add or edit slot information.
Card Model
The model ID of the card configured for the slot.
Card Description
The description of the card configured for the slot.
Use the buttons to perform the following tasks:
•
To preconfigure a card before adding it to a slot, click
Add
and configure the desired settings.
•
To change slot or card settings, select the checkbox for the entry and click
Edit
.
•
To delete a slot configuration entry from the list, select the checkbox for each entry to delete and
click
Remove
.
Configuring System Information
ExtremeSwitching 200 Series: Administration Guide
139