Table 291: Server Configuration Fields
Field
Description
Server
The Server IP address or Hostname.
Priority
The order in which the servers are used.
Port
The authentication port.
Key String
The authentication and encryption key for communications between
the device and the server. The key must match the encryption used on
the server.
Connection Timeout
The amount of time that passes before the connection between the device and
the server time out.
Click
Refresh
to update the page with the most current information.
If you make any changes to the page, click
Submit
to apply the changes to the system.
Source Interface Configuration
Use the Source Interface Configuration page to specify the physical or logical interface to use
as the
client source interface. When an IP address is configured on the source interface, this
address is used for all communications between the local client and the remote
server. The IP address of the designated source interface is used in the IP header of
management protocol packets. This allows security devices, such as firewalls, to identify all source
packets coming from a specific device.
To access this page, click
Security
>
>
Source Interface Configuration
in the navigation
menu.
Table 292: Source Interface Configuration Fields
Field
Description
Type
The type of interface to use as the source interface:
•
None – The primary IP address of the originating (outbound) interface is
used as the source address.
•
Interface – The primary IP address of a physical port is used as the source
address.
•
VLAN – The primary IP address of a VLAN routing interface is used as the
source address.
•
Network – The network source IP is used as the source address.
•
Service Port – The management port source IP is used as the source address.
Interface
When the selected Type is Interface, select the physical port to use as the source
interface.
VLAN ID
When the selected Type is VLAN, select the VLAN to use as the source interface.
The menu contains only the VLAN IDs for VLAN routing interfaces.
Click
Refresh
to update the page with the most current information.
If you make any changes to the page, click
Submit
to apply the changes to the system.
Managing Device Security
ExtremeSwitching 200 Series: Administration Guide
291