AXP 64 C AT • SIS Configuration and Control
35
3.
On the
Device
Info
screen, locate the name of your AXP. The IP address is in the
Primary
Address
column (see the example in figure 30,
1
).
Figure 30.
AXP IP Addresses on the Dante Controller Device Info Screen
4.
Connect the AXP to the control computer using a host communication utility such as
Extron DataViewer (available at no charge from
).
5.
Enter the IP address and port number (
4333
) into the control device or DataViewer. The
AXP 64 C AT responds with a copyright message, the name of the product, firmware
version, and part number (see
AXP 64 C AT-initiated Messages
).
The AXP is ready to accept SIS commands immediately after it sends the copyright
message.
Using SIS Commands
AXP 64 C AT-initiated Messages
If the AXP 64 C AT is powered off, the PC is cabled to the AXP 64 C AT, and DataViewer is
set up and running on the PC, the connected AXP sends the following message when first
powered on:
©
Copyright
20
nn
,
Extron,
AXP
64
C
AT,
V
n.nn
,
60-1499-01
V
n.nn
is the firmware version number.
No response is required from the host.
SIS Command Sets
Although the AXP 64 C AT uses the same structure for all SIS commands, three categories
of SIS commands are used with the AXP 64:
•
Basic global SIS commands (see
•
DSP SIS commands (see
•
Although both types of commands use the same structure of basic SIS commands, they
differ in how the software addresses the individual processor blocks within the AXP 64 C AT.