background image

2

Preparing the Table

WARNING:

  Wear safety glasses when cutting the hole in the table. Failure to comply may result in eye injury.

ATTENTION

:

    •   The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.

 

   •  

Exercise care to prevent scarring or damaging the furniture.

 

   • 

 

Cable Cubby 300 installation — Ensure that the table surface is at least 5/8 inch (0.625

"

) (15.88 mm) thick.

 

   •  

Cable Cubby 600/800 installation — Ensure that the table surface is at least 3/4 inch (0.75

"

) (19.05 mm) thick.

Cut a hole in the surface where the enclosure will be installed. There are three methods for cutting the hole in the table:

 

z

A hand router and the appropriate Extron Cable Cubby routing template. 

HSA 200

USER A

CCESS

HSA 200

CABLE CUBBY 300

CABLE CUBBY 300

USER A

CCESS

 

See the table below for part numbers. See the 

HSA Series and Cable Cubby 

Routing Template User Guide

, available on the Extron website, 

www.extron.com

to prepare the template and use the template to cut the hole.

NOTE:

  The metal routing template is reusable. Do not discard this 

routing template when the installation is complete.

 

z

A CNC wood router and the exact cut-out dimensions for your model. See the 
table below for cut-out dimensions:

 

z

A jigsaw and a paper cut-out template (available on the Extron website, 

www.extron.com

)

NOTE:

  The underlined dimension in the table below is the side on which 

the lid opens.

Routing Template 

Part Number

Cut-out Dimensions

Product

Width

Depth

Cable Cubby 300S

70-237-01

4.65 inches (11.81 cm)

6.00 inches (15.24 cm)

Cable Cubby 300C

70-237-01

6.03 inches (15.32 cm) diameter

Cable Cubby 600

70-239-01

6.49 inches (16.48 cm)

6.49 inches (16.48 cm)

Cable Cubby 800

70-240-01

7.89 inches (20.04 cm)

6.35 inches (16.13 cm)

Preparing the Cable Cubby

TIPS:

 •  Install any power modules before installing AAPs.

 

• 

Populate the shelf brackets with cables and AAPs outside the enclosure and then 
install the populated AAP shelf assembly into the enclosure.

Install the power module and cables in the pass-through holes as follows:

1. 

Gently push any power modules into the desired position and elevation. Secure the 
modules into position with the provided screws and washers.

WARNING:

  To ensure good electrical grounding, use the star washers with the 

screws.

2. 

Rest the cables in the half-moon cutouts of two cable pass-through AAP segments (

Ç

and secure the next cable pass-through AAP segment to the shelf brackets with the 
provided #4-40 nuts (

É

).

3. 

Repeat step 2 for the remaining cables and cable pass-through AAP segments.

4. 

Snap the appropriate size split grommet over each cable and into the pass-through holes 
with the flange of the grommet on top.

5. 

Snap the included hole plugs into unused hole.

6. 

Gently push the AAP shelf assembly into the enclosure at the desired elevation. 
Ensure there is enough space above the AAP assembly for the Cable Cubby lid to close 
completely. Secure the AAP shelf assembly into position with the provided screws.

TIP:

  If the AAP shelf assembly does not slide easily into the cubby, loosen the AAP 

mounting nuts. Retighten the nuts once the AAP shelf assembly is installed.

User Access

Cut-Out 

Template f

or Extron's

Cable Cubb

y 200

.350" (0.90 cm

)

Print this

template

 

at 100%

Trim Ring 

Lip

Trim Ring’

s Outer Edge

0.00”

 (0.00 cm)

0.02 (0.05 cm)

+

1. Confirm Pr

oduct to be installe

d

2. Measure cutout and template

3. Af

ter

 ch

ecking,

 cut opening

e

g

1

1

6

2b

4

2a

Cable Cubby 800

Shelf
Bracket

AAP
Shelf
Assy.

Cable Cubby • Setup Guide (Continued)

Summary of Contents for Cable Cubby 300C

Page 1: ...e in the table c Hand router and template c CNC wood router c Jigsaw and paper template Before starting the installation check with local and state regulations c Ensure that the planned installation complies with building and electrical codes c Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements Tools and Equipment Required for...

Page 2: ...ches 16 48 cm Cable Cubby 800 70 240 01 7 89 inches 20 04 cm 6 35 inches 16 13 cm Preparing the Cable Cubby TIPS Install any power modules before installing AAPs Populate the shelf brackets with cables and AAPs outside the enclosure and then install the populated AAP shelf assembly into the enclosure Install the power module and cables in the pass through holes as follows 1 Gently push any power m...

Page 3: ...nlarge the opening 3 Under the table install the screw clamps on the enclosure at a height at which the clamp will reach the underside of the tabletop ATTENTION Do not overtighten the Phillips head screws on the screw clamps Overtightening can bend the screw clamp 4 Snugly tighten the Phillips head screws on the screw clamps to secure the enclosure to the surface 5 Tighten the locking thumbscrews ...

Page 4: ...bby AC Power Cord Extron Headquarters 800 633 9876 Inside USA Canada Only Extron USA West Extron USA East 1 714 491 1500 1 919 850 1000 1 714 491 1517 FAX 1 919 850 1001 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 4000 EXTRON ...

Reviews: