![background image](http://html.mh-extra.com/html/extron-electronics/da2-hd-4k/da2-hd-4k_user-manual_2455143030.webp)
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Verbose Mode
Set verbose mode
EX1)
CV
}
Vrb
X1)]
Sets verbose mode (
X1)
).
View verbose mode
E
CV
}
X1)]
Unit Name
Set the unit name
EX*
CN
}
Ipn
•
X*]
Sets the unit name (
X*
).
Reset unit name to factory
default
E
•
CN
}
Ipn
•
DA-HD-4K-
SERIES
]
Default unit name is
DA-HD-4K-
SERIES
View unit name
E
CN
}
X*]
Others
View unit part number
N
60-1480-01
]
60-1481-01
]
60-1482-01
]
DA2 HD 4K
DA4 HD 4K
DA6 HD 4K
View firmware version
Q
X&]
Firmware build (
X&
)
Reset
E
ZXXX
}
Zpx
]
NOTES:
X&
= Firmware build to two decimal places (
x.xx
)
X*
= Unit name: a
text string of up to 24 characters. (Alphanumeric characters and hyphens only. No
distinction between upper and lower case. No spaces. First character must be a letter and the
last character cannot be a hyphen.)
X1)
= Verbose mode (
0
= Clear or none;
1
= Verbose mode;
2
= Tagged responses for queries;
3
= Verbose mode and tagged responses for queries)
DA HD 4K Series • SIS Commands