Revision Date:
10/16/2020
Page 8 of 28
DMP Plus Series C V / C V AT – Patton POTS
•
Using Extron
connect to the Patton POTS interface via RS-232
o
Download the attached file “DataViewer Set Patton IP address.txt” from the PDF
to download the files from the PDF
o
Open Extron
o
Click Connect from the toolbar
File -> Connect (ALT+E)
o
Select the RS-232 Tab
Setup the port:
•
Com Port (select COM port on your computer)
•
Baud Rate:
9600
•
Parity Bit:
None
•
Data Bit:
8
•
Stop Bit:
1
•
Handshake: None
o
Press OK/Enter until you see “login:”
•
Once connected to the Patton and you see
login:
•
In DataViewer select “Run Script from the menu bar
o
Tools -> Send Script File ( ALT + F )
o
Select DataViewer Set Patton IP address.txt and Click Open
to download the files from the PDF
•
The Script will set the IP address to
o
192.168.1.253 / 255.255.255.0