background image

DTP2 T 204 • Setup Guide

The Extron DTP2 T 204 is an HDCP-compliant, four 
input HDMI switcher with a DTP2 output that switches 
and extends digital embedded audio, bidirectional 
RS-232, IR, and remote power. 
It supports video resolutions up to 4K @ 60 Hz and 
1080p @ 120 Hz, using shielded twisted pair cabling as 
a transmission medium, and extends HDMI video signals 
up to 330 feet (100 meters).
The switcher features four HDMI inputs and a 
DTP2/HDBT output, data rates up to 18 Gbps, HDR, 
12 bit Deep Color, 3D, Lip Sync, HD lossless audio 
formats, and SIS to CEC control. EDID Minder® 
maintains EDID communication with connected devices 
and ensures that the HDMI sources power up properly 
and maintain correct video output.
Control is available via front panel buttons, USB, Extron 
Product Control Software (PCS), Ethernet, RS-232, 
contact closure, and auto-input switching for integration 
with any control system. Front panel LED indicators provide immediate visual confirmation of HDCP authentication and signal 
presence for each input and output. Remote power for the end unit is available via the DTP output. 
This guide provides instructions for an experienced installer to set up and operate this switcher. For full installation, 
configuration, and operation details, see the 

DTP T 204 User Guide

, available at 

www.extron.com

.

Rear Panel Features and Connections

INPUTS

OVER TP

DTP2 T 204

1

2

3

4

LAN

RS-232

IR

Tx Rx G Tx Rx

LINK

SIG

OUT

Tx

T

T C

C

T +V

T C

T

G

+V

C

T

G

+V

C

C

1

2

3

4

5

6

Rx

RS-232

G

2.2 A

  MAX

POWER

12V

REMOTE

CONT

HDBT

DTP

SEND POWER

OFF

A

B

C D E

F

G H

F

I

Figure 1. 

DTP2 T 204 Rear Panel

Installation Steps

1. 

Turn off and disconnect all of the equipment

 from the power source.

2. 

Mount the switcher

 on a rack shelf or furniture (optional).

3. 

Connect HDMI input sources

 to one or more of the DTP2 T 204 inputs (see figure 1, 

B

). The default (Extron) EDID is 

present at each input and Hot Plug Detect (HPD) is actively controlled on each input.

NOTES:

 

• 

The default (Extron) EDID is 1080p @ 60 Hz (see the 

DTP2 T 204 User Guide

 for the 

EDID table).

• 

LockIt

®

 cable lacing brackets are provided to secure the HDMI cables to the rear panel 

connectors to reduce stress on the HDMI connectors and prevent signal loss due to 
loose cable connections (see the 

LockIt Lacing Brackets

 on page 4).

4. 

Connect the input of a DTP2 or HDBaseT compatible device

 to the DTP/HDBT OUT  

RJ-45 connector (

C

). See the image at right to wire the connector.

INPUTS

OVER TP

DTP2 T 204

1

2

3

4

LAN

RS-232

IR

Tx Rx G Tx Rx

LINK

SIG

OUT

Tx

T

T C

C

T +V

T C

T

G

+V

C

T

G

+V

C

C

1

2

3

4

5

6

Rx

RS-232

G

2.0 A MAX

POWER
12V

REMOTE

CONT

HDBT

DTP

SEND POWER

OFF

L

RS-232

IR

Tx Rx

Tx Rx

G

R

POWER

12V         
--A MAX

AUDIO

OUTPUTS

OVER DTP2

SIG         LINK

DTP2 IN

POWER

12V         

0.3A MAX

IPL PRO S3

G

Tx Rx

RTS CTS

G

Tx Rx

RTS CTS

G

Tx Rx

RTS CTS

COM 1

COM 2

COM 3

LAN / PoE

SHARE

SHARE

SHARE

MODEL 80

FLAT PANEL

LAN

LAN

ON

OFF

MUTE

HDMI

Ethernet

Extron

DTP2 T 204

Transmitter

Extron

IPL Pro S3

IP Link Pro 

Control Processor

Extron 

DTP2 R 211

Receiver

Ethernet

CATx Cable 

up to 330' (100 m) 

Flat Panel Display

HDMI

RS-232

Extron

CCR 30

Contact Closure Remote 

with Three LED Switches

ON/OFF/MUTE Control

Extron 

HDMI SM

Show Me Cables

 

 

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Blue

TIA/EIA T

568 B

TP Wires

12345678

Pins:

5

Pin

1

2
3

6
7
8

4

Power input connector

B

 

HDMI input connectors

C

 

DTP/HDBT Output RJ-45 port

D

 

TP mode switch

E

 

Over TP RS-232 and IR port

F

 

Contact input and

 

tally output 

 

ports with +V connectors

G

 

Remote RS-232 port

H

 

LAN RJ-45 port

I

 

Remote power toggle switch

1

IMPO

RTAN

T:

IMPO

RTAN

T:

Go to ww

w.extr

on.com 

for the complete

 

user guide

, installation instructions,

 and 

specifications bef

ore connecting the 

product to the po

wer sour

ce.

Summary of Contents for DTP2 T 204

Page 1: ...put sources to one or more of the DTP2 T 204 inputs see figure 1 B The default Extron EDID is present at each input and Hot Plug Detect HPD is actively controlled on each input NOTES The default Extron EDID is 1080p 60 Hz see the DTP2 T 204 User Guide for the EDID table LockIt cable lacing brackets are provided to secure the HDMI cables to the rear panel connectors to reduce stress on the HDMI con...

Page 2: ...ugh Ethernet connect a LAN to the RJ 45 LAN connector see figure 1 H The default IP address of the scaler is 192 168 254 254 the default subnet mask is 255 255 255 0 and the default gateway address is 0 0 0 0 See the diagram in step 4 on the previous page to wire this connector 8 Optional Connect contact closure and tally indicator devices The Contact Tally section of the rear panel B on the previ...

Page 3: ... effectuer un raccordement The power supply must not be permanently fixed to the building structure or similar structures La source d alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une structure similaire These power supplies are not suitable for use in air handling spaces or in wall cavities Ces sources d alimentation ne sont pas appropriées pour une uti...

Page 4: ...hese buttons are disabled but the LEDs continue to light to indicate the selected input The input buttons are also used to initiate a system reset and to enable and disable front panel lockout see the DTP2 T 204 User Guide for more information F Reset button This button initiates three modes of reset for the switcher For the different reset levels press and hold the button while the switcher is ru...

Reviews: