sPeCIFICatIONs

100-240V      1.3A, 50-60Hz

VOL/MUTE
10V

STANDBY

4/8 OHM  50W x 2

1

2

LISTED 17TT

AUDIO/VIDEO

APPARATUS

CLASS 2 WIRING

HPA 502

C

US

LEVEL

1

1

2

1

2

LIMITER/

PROTECT

SIGNAL

2

INPUTS

OUTPUT

REMOTE

0

0

100-240V      1.3A, 50-60Hz

VOL/MUTE
10V

STANDBY

4/8 OHM  50W x 2

1

2

LISTED 17TT

AUDIO/VIDEO

APPARATUS

CLASS 2 WIRING

HPA 502

C

US

LEVEL

1

1

2

1

2

LIMITER/

PROTECT

SIGNAL

2

INPUTS

OUTPUT

REMOTE

0

0

Extron
HPA 502

Audio Power
Amplifier

Extron

Flexible Conduit
Adapter Kit

The conduit adapter 
plate replaces 
the IEC plate

Audio

Voltage gain

HPA 502 / HPA 1001-70V ........................ 16x (24 dB) / 57x (35 dB) 

Audio input

Number/signal type  ............................... 2 stereo/mono, balanced/unbalanced

Connectors  ............................................ (1) 3.5 mm captive screw connector, 5 pole

Impedance  ............................................  >10k ohms unbalanced/balanced, DC coupled

Nominal level ......................................... +4 dBu (1.23 Vrms), balanced

Maximum level  ...................................... +20 dBu (7.75 Vrms), balanced

Input sensitivity

HPA 502 ................................................. +4 dBu (1.23 Vrms)

HPA 1001-70V ........................................  +4 dBu (1.23 Vrms) if driven by one input 

-2 dBu (0.615 Vrms) if both inputs are summed

Stereo channel separation (HPA 502) ...... >75 dB @ 1 kHz

CMRR  .................................................... >75 dB @ 1 kHz

NOTE:

 0 dBu = 0.775 Vrms,  0 dBV = 1 Vrms,  0 dBV ≈ 2 dBu

Audio output

Number/signal type

  HPA 502 .............................................. 1 stereo, 4- or 8-ohm

  HPA 1001-70V ..................................... 1 mono 70 V

Connectors

  HPA 502 ..............................................  (1) 5 mm screw lock captive screw connector,  

4 pole

  HPA 1001-70V .....................................  (1) 5 mm screw lock captive screw connector,  

2 pole

Minimum load impedance

  HPA 502 .............................................. 4 ohms

  HPA 1001-70V ..................................... 100 watts into a 70 V line

Amplifier type ......................................... Class D

Continuous power output with a full load and 1% THD at 1 kHz

  HPA 502 ..............................................  50 watts (rms) per channel at 4 or 8 ohms

  HPA 1001-70V ..................................... 100 watts (rms)

Frequency response ................................ 20 Hz to 20 kHz, ±1 dB

THD + Noise  ..........................................  <0.05% @ 1 kHz at full rated power, 8 ohms  

(HPA 502) or 70 V (HPA 1001-70V)

S/N    ...................................................... >100 dB (unweighted)

Damping factor (HPA 502 only) .............. >100 @ 8 ohms

High pass filter (HPA 1001-70V only) ......  80 Hz, 12 dB per octave (switch selectable)

Control/remote – Amplifier

Control port............................................  (1) 3.5 mm captive screw connector, 5 pole

Pin configurations

  DC volume control (analog) ................  Pin 1 = 10 VDC, pin 2 = volume/mute (10k ohm 

pot.), pin 3 = GND

  Standby power control (contact closure) .. Pin 4 = GND, pin 5 = standby

GenerAl

Power  ....................................................  100 VAC to 240 VAC, 50/60 Hz, internal

Typical .................................................... 20 watts

Quiescent ............................................... 8 watts

Standby ..................................................  <1 watt (triggered by contact closure or after  

1 hour with no signal)

Cooling...................................................  Convection, unvented, with internal heat sinks

Protection ............................................... Clip limiting, thermal, short circuit, DC output

Indication ...............................................  Limiter/Protect LED indicates the onset of clip 

limiting, thermal cycling, short circuit, or DC 

output protection

Rack mount ............................................  Yes, with optional 1U rack shelf, part #60-190-01 

(RSU 129) or #60-604-01 (RSB 129)

Enclosure type  ....................................... Metal

Enclosure dimensions  .............................  1.7" H x 8.7" W x 9.5" D (1U high, half rack wide) 

4.3 cm H x 22.1 cm W x 24.1 cm D

Product weight ....................................... 2.5 lbs (1.1 kg)

Shipping weight  .................................... 7 lbs (4 kg)

Listings ................................................... UL, CUL

UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release; meets UL 

60950 and UL 6500 for safety.

Compliances ...........................................  CE, FCC Class A, VCCI, AS/NZS, ICES,  

ENERGY STAR

® 

qualified amplifier

MTBF ...................................................... 30,000 hours

Warranty  ................................................ 3 years parts and labor

NOTE:

 All nominal levels are at ±10%.

Model 

Version Description 

 Part Number

HPA 502 

100 Watt Two Channel Power Amplifier ..................  60-849-01

HPA 1001-70V 

70 Volt 100 Watt Mono Power Amplifier .................  60-850-01

Optional Accessories

Flexible Conduit Adapter Kit For PS 123 ....................................................  70-228-02
RSB 129 1U 9.5" Deep Basic Rack Shelf .....................................................  60-604-01

Plenum Rated

In many rooms, the space above the ceiling is often used as a return 
air plenum. To ensure safety from potentially harmful heat and smoke 
release in the event of a fire, A/V products installed in ceilings with a 
plenum airspace must comply with safety codes and be specifically 
rated for use in plenum environments. The HPA 502 and  
HPA 1001-70V power amplifiers are both UL 2043 rated to conform 
to heat and smoke release codes for plenum environments. Installing 
an amplifier above a drop ceiling offers flexibility for integrators 
wanting to conserve rack space and achieve a clean, streamlined 
installation free of visible cable runs. An amplifier situated above the 
ceiling is also concealed from view, which prevents the possibility of 
theft.

Flexible Conduit Adapter Kit

The HPA 502 and HPA 1001-70V feature a built-in power supply with 
a modular power connection. In a rack installation, these amplifiers 
would be powered from an AC receptacle. However, when the 
amplifier is to be permanently situated above a drop ceiling, the 
HPA 502 and HPA 1001-70V can be directly hard-wired for AC power 
when the optional Flexible Conduit Adapter Kit, part # 70-228-02, is 
used in place of a conventional power cord. With this kit, the wiring 
is encased in flexible conduit, which connects directly to the amplifier 
and a local junction box. This can simplify installation without the 
necessity to provide an AC receptacle above the drop ceiling. As with 
the HPA 502 and HPA 1001-70V, the Flexible Conduit Adapter Kit is 
plenum-rated and meets UL 2043 for smoke and heat release.

DesCrIPtION

Summary of Contents for HPA 1001-70V

Page 1: ... width enclosure n Auto standby with fast power up n Remote volume and mute control port n Hidden detented rear panel level controls n Multiple protection circuits n Remote standby port HPA 502 HPA 1001 70V The Extron HPA 502 and HPA 1001 70V are compact highly efficient ENERGY STAR qualified audio power amplifiers that are professional grade and feature Class D amplification with patented CDRS Cl...

Page 2: ...onnectors Enables simple secure connections with 22 to 14 AWG speaker cables n Front and rear mounted signal and protection indication LEDs Provide convenient indication of amplifier operation from both sides of an equipment rack n Internal international power supply The Extron HPA 502 and HPA 1001 70V are compact power amplifiers designed for installation in racks and lecterns These ENERGY STAR q...

Page 3: ...tput Indication Limiter Protect LED indicates the onset of clip limiting thermal cycling short circuit or DC output protection Rack mount Yes with optional 1U rack shelf part 60 190 01 RSU 129 or 60 604 01 RSB 129 Enclosure type Metal Enclosure dimensions 1 7 H x 8 7 W x 9 5 D 1U high half rack wide 4 3 cm H x 22 1 cm W x 24 1 cm D Product weight 2 5 lbs 1 1 kg Shipping weight 7 lbs 4 kg Listings ...

Page 4: ...on SI 28 Surface mount Speakers 100 240V 1 3A 50 60Hz VOL MUTE 10V STANDBY 4 8 OHM 50W x 2 1 2 LISTED 17TT AUDIO VIDEO APPARATUS CLASS 2 WIRING HPA 502 C US LEVEL 1 1 2 1 2 LIMITER PROTECT SIGNAL 2 INPUTS OUTPUT REMOTE 0 0 HPA Series AUDIO POWER AMPLIFIER 1 2 LIMITER PROTECT SIGNAL HPA Series AUDIO POWER AMPLIFIER LIMITER PROTECT SIGNAL 100W VOL MUTE 10V STANDBY 80 Hz L MONO R LISTED 17TT AUDIO VI...

Reviews: