ShareLink Pro 500 • SIS Configuration and Control
35
Command
ASCII Com-
mand
(Host to Device)
Response
(Device to Host)
Additional Description
Unit name
Set unit name/hostname
EX3)
CN
}
Ipn
•X3)]
Set unit name/hostname to
default
E•
CN
}
Ipn
•X3!]
Default =
ShareLink-Pro-xx-xx-xx
(where
xx-xx-xx
is the last six digits
of the unique MAC address).
View unit name/hostname
E
CN
}
X3)]
Ipn
•X3)]
View unit name/hostname
(Verbose mode 2/3)
Information
Information request
(
View unit information)
I/i
Inf*Frq
X@•
HdcpI
X1$•
HdcpO
X1$•
Vmt
X1*•
Amt
X1(•
Vol
X2#]
Verbose mode 2/3:
Inf00*Frq
X@•
HdcpI
X1$•
HdcpO
X1$•
Vmt
X1*•
Amt
X1(•
Vol
X2#]
Query firmware version
Q/q
X3@]
View firmware version
Query firmware and build
version
*Q/q
X3#]
View firmware version and build
version
Query internal temperature
E
20STAT
} X3$]
20Stat
X3$]
Query internal temperature
(Verbose mode 2/3)
Query model name
1I/i
<
model
name
>
]
Inf01*<
model name
>
]
View model name
(Verbose mode 2/3)
Query model description
2I/i
<
model description
>
]
Inf02*<
model desc.
>
]
View model description
(Verbose mode 2/3)
Query part number
N/n
<
part number
>
]
Pno<
part number
>
]
View part number
(Verbose mode 2/3)
KEY:
X@
= Input signal
0
= No input signal detected
1
= Input signal detected
X1$
= HDCP status
0
= Not connected,
1
= Not HDCP Encrypted,
2
= HDCP Encrypted
X1*
= Video mute status
0
= Unmute (default),
1
= Mute video,
2
= Mute sync
X1(
= Audio mute status
0
= Unmute (default),
1
= Mute
X2#
= Volume adjustment range
-100
to
0
= (default is
-30dB
)
X3)
= Unit name
Alpha-numeric up to 63 characters. No blanks, spaces, or special
characters except hyphen (-).
X3!
= Default unit name
Alpha-numeric name.
ShareLink-Pro-xx-xx-xx
(where
xx-xx-xx
is the last six digits of the unique MAC address).
X3@
= Firmware version (Ex:
1.00
)
X3#
= Firmware version and build version (Ex:
1.00.0010
)
X3$
= Internal temperature (2 digits, °C)
Summary of Contents for ShareLink Pro 500