ShareLink Pro 500 • SIS Configuration and Control
25
SIS Configuration
and Control
This section contains SIS communication details and SIS commands and responses for the
ShareLink Pro 500. Topics in this section include:
•
•
•
Command and Response Tables for SIS Commands
Host Device Connection
Use a connected computer running an SSH client such as PuTTY to send and receive SIS
commands and responses.
Use port 22023 for connection to the ShareLink Pro when using a control system. Enter the
admin username and password when prompted.
NOTE:
The factory configured password for all accounts have been set to the device
serial number (passwords are case sensitive). Performing a
(see page 7) sets the password to
extron
.
SIS Overview
Host and Device Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the ShareLink Pro determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the device to the host end with a carriage return and a line feed
(CR/LF =
]
), which signals the end of the response character string. A string is one or more
characters.
Error Responses
When the ShareLink Pro receives an SIS command and determines that it is valid, it
performs the command and sends the corresponding response to the host device. If the
command is determined invalid or contains invalid parameters, the device returns an error
response to the host. The error response codes are:
E10
= Invalid command
E11
= Invalid preset number
E13
= Invalid parameter
E14
= Not valid for this configuration
E17
= Invalid command for signal type
E22
= Busy
E24
= Privilege violation
E35
= Account does not exist