Mounting

All these touchpanels can be wall-mounted, either using a UL-listed junction box, an external wall box, or directly into drywall or 
furniture. Suitable mounting accessories can be found at 

www.extron.com

.

ATTENTION:

• 

Do not install touchpanels in a fire resistant rated wall or partition assembly.

• 

Ne pas installer les écrans tactiles sur un mur protégé par un dispositif coupe-feu ou dans une cloison.

• 

All structural steps and electrical installation must be performed by qualified personnel in accordance with local and 
national building codes and electrical codes.

• 

Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualifié, conformément aux 
codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.

Figure 1 shows the TLP Pro 725M. Installation for the TLP Pro 525M or TLP Pro 1025M is very similar.

With a Wall Box or Junction Box

Some local building codes require the touchpanel to be mounted in a junction box. Junction boxes or wall boxes must be purchased 
separately. 

NOTES:

• 

The TLP Pro 525M touchpanels mount to a 1-gang junction box. The TLP Pro 725M and 1025M touchpanels mount to a 
2-gang junction box.

• 

Extron provides four 3/4" #6-32 Philips pan head screws for mounting to US junction boxes

• 

Extron provides two 16 mm M 3.5 Philips pan head screws for mounting to MK junction boxes

• 

EU junction boxes are usually provided with their own screws.

With a wall box 

1. 

Install a junction box or wall box (see figure 1, 

1

), 

following the instructions provided by the manufacturer.

2. 

Fasten the mounting plate to the wallbox (

2

) with 

the provided screws. Use the mounting holes that 
are appropriate to the junction box you are using (see 

figure 2

, on the following page).

3. 

Run and connect cables to the back of the touchpanel 
(see 

Rear Panel Features

 on the following page).

4. 

The TLP Pro 525M mounting plate has two hooks 
(one in each top corner). The TLP Pro 725 M and 
TLP Pro 1025M mounting plate has four hooks (

3

), one 

in each corner (see 

figure 2

).

Position the touch panel so that the mounting slots (see 

figure 4

,

D

) in the rear of the touchpanel align with 

these hooks.

5. 

Move the touchpanel inward and downward so that 
touchpanel sits securely on the hooks and the tongue at 
the bottom of the mounting plate (

4

) sits in the groove 

in the bottom of the touchpanel (see inset, figure 1, 

5

).

6. 

Fasten the touchpanel to the mounting plate with the 
lock screw (

6

).

steps 3 through 6

TOP

e

Back View

1

2

3

4

5

6

4

Figure 1. 

Mounting the TLP Pro 725M with a Junction Box

figure 1

Summary of Contents for TLP Pro 525M seriesl

Page 1: ... DHCP status on or off If DHCP is off you must also obtain IP address Subnet mask Gateway User name This can be either admin or user Password By default this is extron for either admin or user Make a note of the touchpanel MAC address Mount and Cable All Devices ATTENTION Do not power on the touchpanels or control processors until you have read the Attention in the Rear Panel Features section of t...

Page 2: ...he TLP Pro 725M and 1025M touchpanels mount to a 2 gang junction box Extron provides four 3 4 6 32 Philips pan head screws for mounting to US junction boxes Extron provides two 16 mm M 3 5 Philips pan head screws for mounting to MK junction boxes EU junction boxes are usually provided with their own screws With a wall box 1 Install a junction box or wall box see figure 1 1 following the instructio...

Page 3: ...TLP Pro 725M The front panels of all the touchpanels have the same features and are almost identical apart from the size A A B B C C A A D D E E E E Figure 3 TLP Pro 725M Front Panel A Motion sensor Detects motion between three to five feet from the touchpanel and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode Wh...

Page 4: ...D D D D K K D D D D I I J J TLP Pro 1025M Figure 4 TLP Pro 525M 725M and 1025M Rear Panels NOTE The panels shown in figure 4 are for illustration only and are not to the same scale For more information follow these links to the next page A Menu Button B Reset Button C Reset LED D Mounting Slots E Digital Input Monitoring Port F LAN PoE Connector G USB Port H Speaker I Slot for Mounting Plate J Mou...

Page 5: ...025 Series User Guide Le TLP Pro 525M le TLP Pro 725M et le TLP Pro 1025M supportent l alimentation via Ethernet PoE 802 3af classe 3 Veuillez lire la partie Attention dans la section Rear Panel Features du TLP Pro 525 725 and 1025 Series User Guide avant de mettre sous tension les écrans tactiles NOTE These touchpanels are shipped without a power injector The power injector must be purchased sepa...

Page 6: ...efaults Press and hold the Reset button for 9 seconds After the Reset LED flashes three times release and momentarily press the Reset button Use this mode to return the touchpanel to factory default settings Status Display Audio Advanced Exit Network Info Model TLP Pro 725M Part Number 60 1563 02 Firmware Version 1 02 0001 b001 Network IP Address DHCP Host Name Off 192 168 254 251 TLP AB CD EF Dis...

Reviews: