background image

1

IMPOR

TANT

:

Go to 

www

.extron.com

 for the

complete user guide and installation

instructions befor

e connecting the

product to the power sour

ce.

TLP Pro 1220, 1520, and TLP Pro 1720TG • Setup Guide

Overview

The Extron TLP Pro 1220TG, TLP Pro 1520TG, and TLP Pro 1720TG are table-top touchpanels with high resolution capacitive touch 
screens. 

The TLP Pro 1220TG has a 12.1 inch screen with a 1280x800 resolution. The TLP Pro 1520TG has a 15.6 inch screen 

with a 1366x768 resolution. The TLP Pro 1720TG has a 17.3 inch screen with a 1920x1080 resolution. They are ideal for any 
AV applications requiring large touchpanels with flexible mounting options and fully customizable interfaces. This guide provides 
instructions for experienced installers to mount and install these touchpanels. For more complete procedures, see the 

TLP Pro 1220, 

TLP Pro 1520, and TLP Pro 1720 Series User Guide

 at 

www.extron.com

.

Setup Overview and Checklist

Get Ready

 

…

Download and install the latest version of the following software:

• 

GUI Designer

 — For designing layouts for Extron TouchLink® Pro touchpanels and third party touch interfaces.

• 

Global Configurator

®

 Plus and Professional

 — For setting up and configuring the control processor and touchpanel.

• 

Toolbelt

 — For device discovery, device information, firmware updates, and configuration of network settings, system 

utilities, and user management for TouchLink Pro devices.

• 

Global Scripter

®

 — Provides an integrated development environment for Extron control systems programming.

NOTE:

  All four software programs are available from 

www.extron.com

.

 

…

Obtain the following network information from your network administrator:

 

…

DHCP status

 (on or off). If DHCP is off, you also require:

 

…

IP address

 

 

…

Subnet mask

 

…

Gateway

 

…

Username

 — This can be either 

admin

 or 

user

.

 

…

Passwords

  — The factory configured passwords for all accounts on this device have been set to the device serial number. 

Passwords can be changed during configuration. Passwords are case sensitive 

NOTE:

  If the device is reset to default settings, the passwords are reset to the default password, which is extron (for 

either admin or user).

 

…

Make a note of the touchpanel MAC address.

Mount and Cable All Devices

ATTENTION:

• 

Do not power on the touchpanels or control processors until you have read the Attention in the Power Supply section of the 

TLP Pro 1220, TLP Pro 1520, and TLP Pro 1720 Series User Guide

 or the 

IPL Pro User Guide

.

• 

Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section « sources 
d’alimentation » du 

TLP Pro 1220, TLP Pro 1520, and TLP Pro 1720 Series User Guide

 ou du 

IPL Pro User Guide

.

 

…

Mount the units. There are several mounting options for TouchLink Pro touchpanels (see 

Mounting

 on the following page). 

 

…

Connect cables to the touchpanels. To connect cables, remove the back and base covers (see 

figure 1

 on the following page). 

For more information about the cable connectors, see 

Rear Panel Features

 on page 4.

 

…

Connect the power cords and power on all devices.

Set up the Touchpanels for Network Communication

 

…

Connect the PC that you will use for setup, the control processor, and touchpanel 

to the same Ethernet subnetwork

.

 

…

Use the 

Setup Menu

 (see page 5) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway, 

and related settings for the touchpanel.

Configure the Touchpanels

 

…

Create a graphical user interface with GUI Designer (see 

GUI Designer Help File

 for step-by-step instructions).

 

…

Associate functions with the graphical user interface features by configuring (see the 

Global Configurator Help File

) or 

programming (see the 

Global Scripter Help File

) the system. Global Scripter provides an Extron-exclusive Python library 

(ControlScript

®

) and Global Scripter modules to get you started.

Summary of Contents for TouchLink TLP Pro 1220 Series

Page 1: ...words The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords are case sensitive NOTE If the device is reset to default settings the passwords are reset to the default password which is extron for either admin or user Make a note of the touchpanel MAC address Mount and Cable All Devices ATTEN...

Page 2: ...ed with stands that allow the units to be placed on any suitable flat surface for example a desk table or lectern Fixed Mounting Figure 2 shows the base of the TLP Pro 1220TG with the cover removed to indicate the position of the mounting holes The bases of the TLP Pro 1520 TG and TLP Pro 1720TG are similar and the spacing of the mounting holes figure 2 1 is identical 1 Mark the location for two h...

Page 3: ...e enabled and disabled using the Setup Menu see page 6 B Status light can be programmed to provide system feedback The LED light bar is located above the screen C Ambient light sensor monitors ambient light level and adjusts screen brightness D Capacitive touch screen provides simple control of AV systems The TLP Pro 1220TG has a 12 1 inch screen with a 1280x800 resolution The TLP Pro 1520TG has a...

Page 4: ... your XTP product LAN input Connect the touchpanel to the LAN using a twisted pair cable terminated with an RJ 45 connector PoE input the connector can be used with a PoE power injector Connect the cables as shown in figure 6 which shows the Extron PI 140 power injector recommended by Extron NOTE Some XTP models are able to remotely power these touchpanels but not all have that capability Go to th...

Page 5: ...y press the Reset button Use this mode to return the interface to factory default settings NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords are case sensitive If the device is reset to default settings the passwords are reset to the default password which is extron for either adm...

Page 6: ... Audio Input and Advanced by pressing the appropriate button in the navigation bar at the top of the screen for more information see the TLP Pro 1220 TLP Pro 1520 and TLP Pro 1720 Series User Guide Figure 7 shows the setup menu for the TLP Pro 1220TG The setup menus for the TLP Pro 1520TG and TLP Pro 1720TG are very similar Press the Menu button for at least 3 seconds to open the calibration scree...

Reviews: