Result
The unit reverts to factory-installed firmware. Event scripting does not start if the unit is
powered on in this mode. All user files and settings, adjustments, and IP settings are
maintained.
NOTE:
To return the unit to the firmware version that was running prior to the reset, cycle
power to the unit.
Reset All IP Settings
This mode resets all IP settings to factory defaults.
Activation
To reset all IP settings:
1.
Hold down the
Reset
button (see
, on page 6) for about 6 seconds until
the Reset LED (
) blinks twice (once at 3 seconds, again at 6 seconds).
2.
Release and press the
Reset
button momentarily (for <1 second) within 1 second.
Nothing happens if the momentary press does not occur within 1 second.
Result
•
Sets the DHCP back to factory default (
Off
).
•
Sets the Hostname back to factory default (
TLP-Pro-300M-AB-CD-EF
).
•
Sets the IP address back to factory default (
192.168.254.251
).
•
Sets the Subnet Mask address back to factory default (
255.255.255.0
).
•
Sets the Gateway address back to the factory default (
0.0.0.0
).
•
Sets the DNS Primary address back to the factory default (
127.0.0.1
).
•
Sets the Domain name back to factory default (Blank).
Reset to Factory Defaults
This mode resets all IP settings and touchpanel settings, including passwords, to factory
defaults and removes all configurations. It allows you to start over with configuration and
uploading.
NOTES:
•
The factory configured passwords for all accounts on this device have been set to the
device serial number. Passwords can be changed during configuration. Passwords
are case sensitive.
•
If the device is reset to default settings, the password is the default password
configuration. The default password is
extron
(for either
admin
or
user
accounts).
Activation
To reset the unit to all factory default settings:
1.
Hold down the
Reset
button for about 9 seconds until the Reset LED blinks three times
(once at 3 seconds, again at 6 seconds, again at 9 seconds).
2.
Release and press the
Reset
button momentarily (for <1 second) within 1 second.
Nothing happens if the momentary press does not occur within 1 second.
Result
Reset to Factory Defaults mode performs a complete reset to factory defaults (except the
firmware).
•
Does everything Reset All IP Settings mode does.
•
Removes touchpanel user interface layout and configurations.
•
Resets all touchpanel settings to factory default.
TLP Pro 300M • Reference Material
29
Summary of Contents for TouchLink TLP Pro 520M