Data
Interface
is a read-only field that reports which of the
CAT 5
(by default) or
SFP
connectors is currently active on LAN 2.
•
Multicast
TTL
(Time to Live) defines the number of hops multicast traffic makes
between routed domains when it exits a source.
Licensed Features
(
,
3
, on the previous page) — allows you to license
features on the VNM 250 series of units. Since all VNM 250 units are supplied fully licensed,
the
license
management
button is not needed by an end user and should not be used.
Configuration
4
) — allows you to configure the video attributes of the source
(
VideoPort
link), the audio attributes of the source (
AudioPort
link), the data attributes
(
Data
link), or the display attributes and source selection.
Video Stream Input Configuration
Click on the
videoPort0
link (
,
4
) to configure the video input. The
Configure
tab for videoPort0 opens:
Configure (VideoPort0) tab
Figure 30.
VideoPort0 Tab
The
Device
List
,
Device
,
Configure
,
Bandwidth
, and
Video
Setup
tabs are available.
The
Upgrade
and
Peripherals
are no longer available.
By default the video port is named
videoPort0
. If required, change the name by editing the
Name
field and clicking
update
.
The top panel provides information about:
•
Input
Mode
— shows the operating mode of the input. Normally this should show
auto
. It is controlled in the
(see page 53).
•
Current
Mode
— shows the currently detected source type.
•
Source
Status
— describes the video input connection.
Active
means the video
source has been recognized at the input.
Unplugged
means either no source is
connected or there is no active video signal from the connected source.
Video input — EDID settings
Set the EDID (D) for the digital video input and the EDID (A) for the analog input. In most
cases, transparent is the correct option. This allows the EDID data of the loop-through
display to pass through the VNE 250 to the source PC.
VNM 250 • VNM 250 GUI Overview