To configure the XMP 240 C AT in redundant mode using Dante Controller:
1.
Open Dante Controller.
2.
Press <
Ctrl+D
> on the keyboard to access the
Device View
dialog box.
3.
Select the desired XMP 240 C AT from the
(Choose a Dante Device...)
drop-down
1
).
4.
Select the
Network Config
tab (
2
).
5.
From the
Dante Redundancy
panel, use the drop-down to select
Redundant
(
3
).
Figure 132.
Redundant Mode Configuration in Dante Controller
To configure the XMP 240 C AT in redundant mode using DSP Configurator:
1.
Use DSP Configurator to connect to the XMP 240 C AT in Live mode (see
2.
Select
Tools > Device Settings
.
3.
In the
Device Settings
dialog box, use the right navigation arrow (
) to navigate to
and select the
Dante Device
tab (see figure 133,
1
).
4.
Select
Enable Redundant Mode
(
2
).
5.
Select
DHCP
or
Static IP
and enter a valid redundancy network configuration (
3
).
6.
Click
Apply
(
4
).
Figure 133.
Redundant Mode Configuration in DSP Configurator