USB-MUXDIAG-II – User guide
16/05/2012
00283735-v1
27
Document confidentiel appartenant à Annecy Electronique S.A.S.
Ne peut être diffusé, copié intégralement ou en partie sans autorisation expresse préalable
7.
Troubleshooting
7.1.1.
Indications apportées par l’état LEDS de l’interface
The LEDs indicate:
Blue ON: correct link with the PC.
Blue FLASHING: communication with the PC on the way.
Bleu OFF: No more link with the PC, peripheral deactivated or in stand-by mode ; may
also indicates a trouble with USB.
Green ON: Problem with the embedded software.
Green FLASHING (slow): correct execution of the embedded software.
Green FLASHING (quick) : communication with the PC on the way.
Green OFF: no embedded software, it is needed to reload the software (only if blue
and red LEDs are ON).
Red ON : Correct power supply of the interface.
All LEDs OFF: the interface is not powered or deactivated or in USB stand-by mode.
7.1.2.
Technical support
In case of any failure or help need during or after this installation, please feel free to
contact our technical support « MUX »:
-
E-mail :
support.mux@exxotest.com
-
Phone: +33 (0) 450 02 34 34