The MIC user interface will remember the last adjustment settings when the system is closed and 
re-opened, but you may have several formats of microfilm that requires different setting for 
optimum performance, note these settings and keep them close to system for reference. 

Video Resolution 

     

Video resolution is optimum at 2592x1944 (5MP). 

Adjusting to the next setting down 

2048x1536 (3MP) will provide a faster refresh rate ( less latent movement of image) and 
almost the same scan / print result 

so try that setting if you prefer a faster refresh rate when 

searching for images.   

After image is located, the Video Resolution can be maximized with the slider in an instant. All 
digital microform viewer/scanners have a measure of image latency which gets a little getting 
used to. After several uses you will become accustomed to the operation of the unit. 

 

 

 
 
 

 

Install  Snagit  Software,  check  all  boxes  during  install,  accept 
license  agreement,  check  30  Day  Eval  (A  full  license  code  is 
provided on the DVD label for future use).  
 
Snagit  will  launch  after  installed  so  review  the  following 
section  to  set  up  Snagit  for  optimum  functionality,  speed  and 
ease of use. 

 
 
 

Summary of Contents for Micro-Image Capture 2

Page 1: ...1 Micro Image Capture 2 Installation User Manual July 2011 v_us1...

Page 2: ...al to get image to the approximate size desired while in Full Screen Mode and then focus using rough focus dial Once focus is close to optimum use the Zoom Dial again to fine focus the image even more...

Page 3: ...t of the unit and push down on the curved glass lift bracket to lift glass and insert the microfiche Flip or rotate fiche until orientation is correct on screen Power Switch Turns the illumination lam...

Page 4: ...rd providing high resolution streaming video with matched monitor will provide the best very best image viewing and capture quality To view and capture these Portrait and Landscape microfilm images at...

Page 5: ...You may use the Micro Image Capture Software to capture images but we strongly recommend using Snagit instead as it offers increased functionality speed and ease of use If you do capture images with...

Page 6: ...egible image in the grey scale mode Dark portions of your image should be as black as possible while light portions should be white not gray 7 Adjust Gamma to remove excess gray in the background of t...

Page 7: ...te the scan button using the Micro Image Capture program we however recommend using Snagit exclusively Zoom and focus the image so that the displayed microfilm image is as close to its full original s...

Page 8: ...view for some and saves on toner consumption if printing Clicking this icon will activate the grey scale mode removing color from the image and displaying in shades of grey only Clicking this icon ac...

Page 9: ...MIC interface to scan and capture images instead of the Snagit software thumbnails of images scanned will appear on the left side scan result area Clicking on an image thumbnail will open the image i...

Page 10: ...me scan print result so try that setting if you prefer a faster refresh rate when searching for images After image is located the Video Resolution can be maximized with the slider in an instant All di...

Page 11: ...scan print and invert negative images to achieve a positive output It is therefore critical that you read the next section carefully and follow the directions step by step to insure proper operation o...

Page 12: ...12 The Snagit Control Panel You will be using the Capture tab at the top of the user interface to make many of the adjustments to Snagit that follow...

Page 13: ...t to capture multiple portions of an on screen image and want them combined on your print and or image file you can check the Multiple Area option This will allow you to drag multiple boxes around are...

Page 14: ...utput Properties At the top of the user interface click on Capture tab then mouse over Output and finally click on Properties Here you will configure the output properties for each output chosen The f...

Page 15: ...7 Now click the button next to your printer that says Printer Properties and configure your printer so that it will by default print the orientation you have selected Click O K and exit the output pr...

Page 16: ...ut You will have to experiment with brightness and contrast settings here capture sample images and continue to adjust until the output meets your requirements Check the Image Resolution effect and se...

Page 17: ...gs used to achieve that particular scan print Safety precautions Observe the following guidelines to ensure that your Micro Image Capture 2 will operate safely and to prevent defects Do not use this d...

Page 18: ...mark for most applications Contrast Contrast enables you to control the ratio between dark and light according to your own preference Use the slider to find your preferred setting With negative micro...

Page 19: ...l manual or otherwise without prior written permission from Micro Image Capture LLC The Micro Image Capture 2 was designed and is a patented by Micro Image Capture LLC and is distributed by authorized...

Reviews: