- 14 -
Eyeheight Limited, Sutton Business Centre, Restmor Way, Wallington, Surrey SM6 7AH
Reg. No. 2855535 Telephone: +44 (0) 208 255 2015 Fax: +44 (0) 208 241 6951 email: sales@eyeheight.com
below. After power up the Status light should turn from red to orange indicating
that it is operational in FP-9 panel mode. If the status light goes green then the
system was factory configured for operation with a soft panel. In the unlikely
event that the status light stays red then the system has found an error and it will
need returning to the factory.
2-2 LE-2n Power and control connection using an FP-9.
The Ethernet cable must be <2M long or you may experience fading of the FP-9
display due to voltage drop from the power supply in the LE-2n. If you wish to
mount the FP-9 panel very remotely (up to 150 Metres) then set the power switch
on the RR-9 (Rear box for the FP-
9) to “LOC” (Local) and use the power supply
supplied with the RR-9 to power the panel.