- 27 -
Eyeheight Limited, Sutton Business Centre, Restmor Way, Wallington, Surrey SM6 7AH
Reg. No. 2855535 Telephone: +44 (0) 208 255 2015 Fax: +44 (0) 208 241 6951 email: sales@eyeheight.com
The sharpn
ess settings affect „large edges‟, whilst the texture settings affect
„small edges‟.
The H parameter adjusts the Horizontal sharpness/texture, range 0-63.
The V parameter adjusts the Vertical sharpness/texture, range 0-63.
The D parameter adjusts the Diagonal sharpness/texture, range 0-63.
The OC parameter adjusts the Overshoot Control for the
sharpness/texture, which is used to minimise ringing on the enhanced
edges. The range for this variable is 0-255.
The enable setting turns on and off the applicable type of enhancement.
There are also a couple more settings that effect the sharpness and texture
adjustment, which are accessed via the menu shown below, found under “Utils
Video
Advncd
Misc.”
Menu window A sets the target of the sharpness and texture enhancement. If
this is set to on, edge sharpening and texture enhancement is applied to the Y
(Luma) channel only. If set to off, edge sharpening and texture enhancement is
applied to RGB channels independently.
Menu window B sets the Noise Adaption threshold value. This setting will limit
the effect of the edge sharpening and texture enhancement settings in areas of
video that are noisy, to prevent enhancing noise. The range is 0 (no noise
adaption) to 63 (maximum limiting of enhancement effects in noisy picture areas).
4.5.5
Auto-ARC mode and the Clear all vars function
Settings for these are found in the menu shown below, under “Utils
Global
Setup
Misc.”
Menu window A sets the action taken for the Auto ARC mode function, which is
only used if the active memory is memory #10 (Auto ARC mode) and is only of
use for the
AR-2 MD
, and only then if the unit is being used to up/down scale.
For any fixed input, Auto ARC mode will automatically adjust the aspect ratio if
the selected output standard is different from the input.
For SD in HD out:
AAM=
No Img
Crop
Clear
All
Vars
Sh+Txt
Y only
= OFF
Sh+Txt
NA Lim
= 0