2.4.3
Double Or Triple Parameter Adjustment
A red menu is one in which there are two or three adjustable parameters. In this
case it is necessary to first select the menu by pressing the red Display Button.
When the red button is pressed it will turn green, and either two or three of the
Rotary Controls will flash, indicating that the respective Rotary Control will
operate a corresponding parameter.
2.4.4
Information Display
A yellow menu is one in which only information is displayed.
2.5
Connecting the LE-2n using an FP-9.
The LE-2n is normally shipped for operation with a soft panel. If you have
specifically asked
for the system to operate with a flexipanel then it will be
shipped this way. The control and power connections are shown in the diagram
below. After power up the Status light should turn from red to orange indicating
that it is operational in FP-9 panel mode. If the status light goes green then the
system was factory configured for operation with a soft panel. In the unlikely
event that the status light stays red then the system has found an error and it will
need returning to the factory.
2-2 LE-2n Power and control connection using an FP-9.