24
4.8 Set Capacity Threshold
This function allows to set up the capacity threshold for Command
5.8 Format +
Capacity Check
under main menu. It will be failed when the target device capacity is
below the threshold range, and the red LED will flash to give warning. There are 3
settings.
Capacity
: the size of device capacity which will be used for sorting, and options are OFF
、
128M
、
256M
、
512M
、
1G
、
2G
、
4G
、
8G
、
16G
、
32G
、
64G
、
128G
、
256G
、
512G
、
1T
、
2T. The default is
OFF
.
Tolerance:
the acceptable range of capacity for sorting, and options are OFF, 0~50%.
The default setting is
5%
。
Capacity Definition:
define the standard for capacity conversion. Options are
1MB=1000K and1MB=1024K. The default is
1MB=1024K
。
4.9 Auto Start
This function allows to set up the ready devices of auto start. When the ready devices are
equal to the setting value, the duplicator will start to work automatically without pressing
ENT.
4.10 Display Mode
There are four display modes:
Auto
,
Basic
,
Show Timer
, and
Expert
.
Basic
shows the
copy progress in general;
Show Timer
displays the time used for the task;
Expert
shows the
devices with highest copy speed and lowest copy speed and their copy progress
Use
▲▼to change option
ENT
ENT
ENT
[Set Capacity Thresh>]
Capacity: OFF
[Set Capacity Thresh>]
1M=1000k
Setup Complete!
Use
▲▼to change option
ENT
Use
▲▼to change option
ENT
6.
Setup
[
Setup
]
8. Set Capacity Thresh>
[Set Capacity Thresh>]
Tolerance: 5%
ENT
ENT
[Auto Start]
Ready device Off
4.Setup
[Setup]
9. Auto Start